CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

The Science Underlying COVID-19: Implications for the Cardiovascular System The role of integrated backscatter intravascular ultrasound in characterizing bare metal and drug-eluting stent restenotic neointima as compared to optical coherence tomography Transcatheter Aortic Valve Replacement in Patients With Multivalvular Heart Disease A Controlled Trial of Rivaroxaban After Transcatheter Aortic-Valve Replacement Comparison of Early Surgical or Transcatheter Aortic Valve Replacement Versus Conservative Management in Low-Flow, Low-Gradient Aortic Stenosis Using Inverse Probability of Treatment Weighting: Results From the TOPAS Prospective Observational Cohort Study Pulmonary arterial hypertension in congenital heart disease: an epidemiologic perspective from a Dutch registry A Review of the Role of Breast Arterial Calcification for Cardiovascular Risk Stratification in Women Ten-Year All-Cause Death According to Completeness of Revascularization in Patients With Three-Vessel Disease or Left Main Coronary Artery Disease: Insights From the SYNTAX Extended Survival Study Intravascular Ultrasound Guidance vs. Angiographic Guidance in Primary Percutaneous Coronary Intervention for ST-Segment Elevation Myocardial Infarction - Long-Term Clinical Outcomes From the CREDO-Kyoto AMI Registry Anticoagulation After Surgical or Transcatheter Bioprosthetic Aortic Valve Replacement

Clinical Trial2011 Dec 1;4(6):562-9.

JOURNAL:Circ Cardiovasc Interv. Article Link

Comprehensive intravascular ultrasound assessment of stent area and its impact on restenosis and adverse cardiac events in 403 patients with unprotected left main disease

Kang SJ, Ahn JM, Song H et al. Keywords: stent; imaging; diagnostic coronary restenosis

ABSTRACT


BACKGROUND - We assessed the optimal intravascular ultrasound (IVUS) stent area to predict angiographic in-stent restenosis (ISR) after sirolimus-eluting stent implantation for unprotected left main coronary artery (LM) disease.


METHODS AND RESULTS - A total of 403 patients treated with single- or 2-stent strategies (crushing and T-stent) had immediate poststenting IVUS and 9-month follow-up angiography. Poststenting minimal stent area (MSA) was measured in each of 4 segments: ostial left anterior descending (LAD), ostial left circumflex (LCX) polygon of confluence (POC, confluence zone of LAD and LCX), and proximal LM above the POC. Overall, 46 (11.4%) showed angiographic restenosis at 9 months: 3 of 67 (4.5%) nonbifurcation lesions treated with a single-stent, 14 of 222 (6.3%) bifurcation lesions treated with single-stent crossover, and 29 of 114 (25.4%) of bifurcation lesions treated with 2 stents. The MSA cutoffs that best predicted ISR on a segmental basis were 5.0 mm(2) (ostial LCX ISR), 6.3 mm(2) (ostial LAD ISR), 7.2 mm(2) (ISR within the POC), and 8.2 mm(2) (ISR within the LM above the POC). Using these criteria, 133 (33.8%) had underexpansion of at least 1 segment. Angiographic ISR (at any location) was more frequent in lesions with underexpansion of at least 1 segment versus lesions with no underexpansion (24.1% versus 5.4%, P<0.001). Two-year major adverse coronary event-free survival rate was significantly lower in patients with underexpansion of at least 1 segment versus lesions with no underexpansion (90±3% versus 98±1%, log-rank P<0.001), and poststenting underexpansion was an independent predictor for major adverse cardiac events (adjusted hazard ratio, 5.56; 95% confidence interval, 1.99-15.49; P=0.001).

CONCLUSIONS - With these criteria, IVUS optimization during LMCA stenting procedures may improve clinical outcomes.