CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Diagnosis and Prognosis of Coronary Artery Disease with SPECT and PET Everolimus-Eluting Bioresorbable Scaffolds Versus Everolimus-Eluting Metallic Stents Nonculprit Lesion Myocardial Infarction Following Percutaneous Coronary Intervention in Patients With Acute Coronary Syndrome Canadian spontaneous coronary artery dissection cohort study: in-hospital and 30-day outcomes Anatomical plaque and vessel characteristics are associated with hemodynamic indices including fractional flow reserve and coronary flow reserve: A prospective exploratory intravascular ultrasound analysis Optical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chronic total occlusions” (PRISON IV) trial Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients Prognostic Implication of Thermodilution Coronary Flow Reserve in Patients Undergoing Fractional Flow Reserve Measurement Spontaneous Coronary Artery Dissection: JACC State-of-the-Art Review Incidence and prognostic implication of unrecognized myocardial scar characterized by cardiac magnetic resonance in diabetic patients without clinical evidence of myocardial infarction

Clinical Trial2011 Dec 1;4(6):562-9.

JOURNAL:Circ Cardiovasc Interv. Article Link

Comprehensive intravascular ultrasound assessment of stent area and its impact on restenosis and adverse cardiac events in 403 patients with unprotected left main disease

Kang SJ, Ahn JM, Song H et al. Keywords: stent; imaging; diagnostic coronary restenosis

ABSTRACT


BACKGROUND - We assessed the optimal intravascular ultrasound (IVUS) stent area to predict angiographic in-stent restenosis (ISR) after sirolimus-eluting stent implantation for unprotected left main coronary artery (LM) disease.


METHODS AND RESULTS - A total of 403 patients treated with single- or 2-stent strategies (crushing and T-stent) had immediate poststenting IVUS and 9-month follow-up angiography. Poststenting minimal stent area (MSA) was measured in each of 4 segments: ostial left anterior descending (LAD), ostial left circumflex (LCX) polygon of confluence (POC, confluence zone of LAD and LCX), and proximal LM above the POC. Overall, 46 (11.4%) showed angiographic restenosis at 9 months: 3 of 67 (4.5%) nonbifurcation lesions treated with a single-stent, 14 of 222 (6.3%) bifurcation lesions treated with single-stent crossover, and 29 of 114 (25.4%) of bifurcation lesions treated with 2 stents. The MSA cutoffs that best predicted ISR on a segmental basis were 5.0 mm(2) (ostial LCX ISR), 6.3 mm(2) (ostial LAD ISR), 7.2 mm(2) (ISR within the POC), and 8.2 mm(2) (ISR within the LM above the POC). Using these criteria, 133 (33.8%) had underexpansion of at least 1 segment. Angiographic ISR (at any location) was more frequent in lesions with underexpansion of at least 1 segment versus lesions with no underexpansion (24.1% versus 5.4%, P<0.001). Two-year major adverse coronary event-free survival rate was significantly lower in patients with underexpansion of at least 1 segment versus lesions with no underexpansion (90±3% versus 98±1%, log-rank P<0.001), and poststenting underexpansion was an independent predictor for major adverse cardiac events (adjusted hazard ratio, 5.56; 95% confidence interval, 1.99-15.49; P=0.001).

CONCLUSIONS - With these criteria, IVUS optimization during LMCA stenting procedures may improve clinical outcomes.