CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Heart Failure With Preserved Ejection Fraction in the Young Treatment strategies for coronary in-stent restenosis: systematic review and hierarchical Bayesian network meta-analysis of 24 randomised trials and 4880 patients Intravascular ultrasound-guided implantation of drug-eluting stents to improve outcome: a meta-analysis In vivo intravascular ultrasound-derived thin-cap fibroatheroma detection using ultrasound radiofrequency data analysis Left Main Revascularization With PCI or CABG in Patients With Chronic Kidney Disease: EXCEL Trial Economic and Quality-of-Life Outcomes of Natriuretic Peptide–Guided Therapy for Heart Failure Non-obstructive High-Risk Plaques Increase the Risk of Future Culprit Lesions Comparable to Obstructive Plaques Without High-Risk Features: The ICONIC Study Use of Intravascular Ultrasound Imaging in Percutaneous Coronary Intervention to Treat Left Main Coronary Artery Disease Patient Selection and Clinical Outcomes in the STOPDAPT-2 Trial: An All-Comer Single-Center Registry During the Enrollment Period of the STOPDAPT-2 Randomized Controlled Trial Clinical impact of intravascular ultrasound-guided chronic total occlusion intervention with zotarolimus-eluting versus biolimus-eluting stent implantation: randomized study

Clinical Trial2011 Dec 1;4(6):562-9.

JOURNAL:Circ Cardiovasc Interv. Article Link

Comprehensive intravascular ultrasound assessment of stent area and its impact on restenosis and adverse cardiac events in 403 patients with unprotected left main disease

Kang SJ, Ahn JM, Song H et al. Keywords: stent; imaging; diagnostic coronary restenosis

ABSTRACT


BACKGROUND - We assessed the optimal intravascular ultrasound (IVUS) stent area to predict angiographic in-stent restenosis (ISR) after sirolimus-eluting stent implantation for unprotected left main coronary artery (LM) disease.


METHODS AND RESULTS - A total of 403 patients treated with single- or 2-stent strategies (crushing and T-stent) had immediate poststenting IVUS and 9-month follow-up angiography. Poststenting minimal stent area (MSA) was measured in each of 4 segments: ostial left anterior descending (LAD), ostial left circumflex (LCX) polygon of confluence (POC, confluence zone of LAD and LCX), and proximal LM above the POC. Overall, 46 (11.4%) showed angiographic restenosis at 9 months: 3 of 67 (4.5%) nonbifurcation lesions treated with a single-stent, 14 of 222 (6.3%) bifurcation lesions treated with single-stent crossover, and 29 of 114 (25.4%) of bifurcation lesions treated with 2 stents. The MSA cutoffs that best predicted ISR on a segmental basis were 5.0 mm(2) (ostial LCX ISR), 6.3 mm(2) (ostial LAD ISR), 7.2 mm(2) (ISR within the POC), and 8.2 mm(2) (ISR within the LM above the POC). Using these criteria, 133 (33.8%) had underexpansion of at least 1 segment. Angiographic ISR (at any location) was more frequent in lesions with underexpansion of at least 1 segment versus lesions with no underexpansion (24.1% versus 5.4%, P<0.001). Two-year major adverse coronary event-free survival rate was significantly lower in patients with underexpansion of at least 1 segment versus lesions with no underexpansion (90±3% versus 98±1%, log-rank P<0.001), and poststenting underexpansion was an independent predictor for major adverse cardiac events (adjusted hazard ratio, 5.56; 95% confidence interval, 1.99-15.49; P=0.001).

CONCLUSIONS - With these criteria, IVUS optimization during LMCA stenting procedures may improve clinical outcomes.