CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Ticagrelor Monotherapy Versus Ticagrelor With Aspirin in Patients With ST-Segment Elevation Myocardial Infarction Dual-Antiplatelet Therapy Cessation and Cardiovascular Risk in Relation to Age: Analysis From the PARIS Registry Ticagrelor With or Without Aspirin in High-Risk Patients With Diabetes Mellitus Undergoing Percutaneous Coronary Intervention Low Endothelial Shear Stress Predicts Evolution to High-Risk Coronary Plaque Phenotype in the Future: A Serial Optical Coherence Tomography and Computational Fluid Dynamics Study Diagnostic Accuracy of Angiography-Based Quantitative Flow Ratio Measurements for Online Assessment of Coronary Stenosis Guideline Update on Indications for Transcatheter Aortic Valve Implantation Based on the 2020 American College of Cardiology/American Heart Association Guidelines for Management of Valvular Heart Disease Pooled Analysis of Bleeding, Major Adverse Cardiovascular Events, and All-Cause Mortality in Clinical Trials of Time-Constrained Dual-Antiplatelet Therapy After Percutaneous Coronary Intervention Stroke Complicating Infective Endocarditis After Transcatheter Aortic Valve Replacement Antithrombotic Management of Elderly Patients With Coronary Artery Disease Intravascular ultrasound in the evaluation and treatment of left main coronary artery disease: a consensus statement from the European Bifurcation Club

Clinical TrialVolume 11, Issue 10, May 2018

JOURNAL:JACC Cardiovasc Interv. Article Link

Impact of Optimized Procedure-Related Factors in Drug-Eluting Balloon Angioplasty for Treatment of In-Stent Restenosis

TM Rhee, JM Lee, ES Shin et al. Keywords: drug-eluting balloon; in-stent restenosis; paclitaxel-coated balloonpercutaneous coronary intervention; target lesion failure

ABSTRACT


OBJECTIVES - The aim of this study was to investigate the impact of optimizing procedure-related factors during drug-eluting balloon (DEB) angioplasty on clinical outcomes of drug-eluting stent in-stent restenosis (ISR).


BACKGOURND - Although DEB angioplasty is recommended as a reasonable option for ISR, recurrent target lesion failure (TLF) still occurs in many patients after DEB angioplasty.

METHODES - Consecutive patients with drug-eluting stent ISR treated with DEB (SeQuent Please) were collected from 4 centers in Korea. The primary outcome was 2-year TLF. Procedure-related modifiable independent predictors for TLF and their best cutoff values were determined.

RESULTS - In a total of 256 patients (309 lesions), TLF occurred in 52 patients (20.3%). Modifiable independent predictors of TLF among procedure-related factors were residual diameter stenosis after lesion preparation (residual percentage diameter stenosis [%DS]), DEB-to-stent ratio (BSR), and DEB inflation time (Tinflation), whose best cutoff values were 20%, 0.91, and 60 s, respectively. TLF rates were significantly higher in groups with residual %DS ≥20% (34.7% vs. 12.5%; adjusted hazard ratio: 2.15; 95% confidence interval: 1.86 to 2.48; p < 0.001), BSR ≤0.91 (46.4% vs. 21.9%; adjusted hazard ratio: 2.02; 95% confidence interval: 1.75 to 2.34; p < 0.001), and Tinflation ≤60 s (26.2% vs. 14.0%; adjusted hazard ratio: 1.82; 95% confidence interval: 1.36 to 2.45; p < 0.001). When classifying ISR lesions by combination of procedure-related factors, TLF occurred in 8.3% in the fully optimized procedure group (residual %DS <20%, BSR >0.91, and Tinflation >60 s) and 66.7% in the nonoptimized group (residual %DS ≥20%, BSR ≤0.91, and Tinflation ≤60 s) (p < 0.001).

CONCLUSIONS - Residual %DS after lesion preparation, BSR, and Tinflation were the only modifiable procedure-related factors in DEB angioplasty. Fully optimized DEB angioplasty with optimal lesion preparation, prolonged inflation, and sufficient dilation may play an important role in reducing TLF after DEB angioplasty.