CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Randomized Evaluation of Heart Failure With Preserved Ejection Fraction Patients With Acute Heart Failure and Dopamine - The ROPA-DOP Trial Reduced Leaflet Motion after Transcatheter Aortic-Valve Replacement Study of Two Dose Regimens of Ticagrelor Compared with Clopidogrel in Patients Undergoing Percutaneous Coronary Intervention for Stable Coronary Artery Disease (STEEL-PCI) Why and How to Measure Aortic Valve Calcification in Patients With Aortic Stenosis Combined use of OCT and IVUS in spontaneous coronary artery dissection Primary Prevention Trial Designs Using Coronary Imaging: A National Heart, Lung, and Blood Institute Workshop Transcatheter Aortic Valve Replacement vs Surgical Replacement in Patients With Pure Aortic Insufficiency 1-Year Outcomes After Edge-to-Edge Valve Repair for Symptomatic Tricuspid Regurgitation: Results From the TriValve Registry The Utility of Rapid Atrial Pacing Immediately Post-TAVR to Predict the Need for Pacemaker Implantation Use of IVUS guided coronary stenting with drug eluting stent: a systematic review and meta-analysis of randomized controlled clinical trials and high quality observational studies

Clinical TrialVolume 71, Issue 23, June 2018

JOURNAL:J Am Coll Cardiol. Article Link

High-Sensitivity Troponins and Outcomes After Myocardial Infarction

Odqvist M, Andersson PO, Tygesen H et al. Keywords: biomarkers; coronary angiography; coronary artery disease; coronary revascularization; incidence; prognosis

ABSTRACT

BACKGROUND - It remains unknown how the introduction of high-sensitivity cardiac troponin T (hs-cTnT) has affected the incidence, prognosis, and use of coronary angiographies and revascularizations in patients with myocardial infarction (MI).

OBJECTIVES - The aim of this study was to investigate how the incidence of MI and prognosis after a first MI was affected by the introduction of hs-cTnT.

METHODS - In a cohort study, the authors included all patients with a first MI from the Swedish National Patient Registry from 2009 to 2013. Cox regression was used to calculate hazard ratios (HRs) with 95% confidence intervals (CIs) for risk of all-cause mortality, reinfarction, coronary angiographies, and revascularizations in patients with MI diagnosed using hs-cTnT compared with those diagnosed using conventional troponins (cTn).

RESULTS - During the study period, 47,133 MIs were diagnosed using cTn and 40,746 using hs-cTnT. The rate of MI increased by 5% (95% CI: 0% to 10%) after the introduction of hs-cTnT. During 3.9 ± 2.8 years of follow-up, there were 33,492 deaths, with no difference in the risk of all-cause mortality (adjusted HR: 1.00; 95% CI: 0.97 to 1.02). There were, in total, 15,766 reinfarctions during 3.1 ± 2.3 years of follow-up, with the risk of reinfarction reduced by 11% in patients diagnosed using hs-cTnT (adjusted HR: 0.89; 95% CI: 0.86 to 0.91). The use of coronary angiographies (adjusted HR: 1.16; 95% CI: 1.14 to 1.18) and revascularizations (adjusted HR: 1.13; 95% CI: 1.11 to 1.15) increased in the hs-cTnT group.

CONCLUSIONS - In a nationwide cohort study including 87,879 patients with a first MI, the introduction of hs-cTnT was associated with an increased incidence of MI, although with no impact on survival. We also found a reduced risk of reinfarction alongside increased use of coronary angiographies and revascularizations.