CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

1-Year Outcomes of Patients Undergoing Primary Angioplasty for Myocardial Infarction Treated With Prasugrel Versus Ticagrelor Risk of Myocardial Infarction in Anticoagulated Patients With Atrial Fibrillation Association Between Diastolic Dysfunction and Health Status Outcomes in Patients Undergoing Transcatheter Aortic Valve Replacement Off-hour presentation and outcomes in patients with acute myocardial infarction: systematic review and meta-analysis Canadian SCAD Cohort Study: Shedding Light on SCAD From a United Front Prognostic Value of Fractional Flow Reserve Measured Immediately After Drug-Eluting Stent Implantation Impact of age and comorbidity on risk stratification in idiopathic pulmonary arterial hypertension Long-Term Coronary Functional Assessment of the Infarct-Related Artery Treated With Everolimus-Eluting Bioresorbable Scaffolds or Everolimus-Eluting Metallic Stents: Insights of the TROFI II Trial A sirolimus-eluting bioabsorbable polymer-coated stent (MiStent) versus an everolimus-eluting durable polymer stent (Xience) after percutaneous coronary intervention (DESSOLVE III): a randomised, single-blind, multicentre, non-inferiority, phase 3 trial A Novel Circulating MicroRNA for the Detection of Acute Myocarditis

Clinical TrialVolume 71, Issue 23, June 2018

JOURNAL:J Am Coll Cardiol. Article Link

High-Sensitivity Troponins and Outcomes After Myocardial Infarction

Odqvist M, Andersson PO, Tygesen H et al. Keywords: biomarkers; coronary angiography; coronary artery disease; coronary revascularization; incidence; prognosis

ABSTRACT

BACKGROUND - It remains unknown how the introduction of high-sensitivity cardiac troponin T (hs-cTnT) has affected the incidence, prognosis, and use of coronary angiographies and revascularizations in patients with myocardial infarction (MI).

OBJECTIVES - The aim of this study was to investigate how the incidence of MI and prognosis after a first MI was affected by the introduction of hs-cTnT.

METHODS - In a cohort study, the authors included all patients with a first MI from the Swedish National Patient Registry from 2009 to 2013. Cox regression was used to calculate hazard ratios (HRs) with 95% confidence intervals (CIs) for risk of all-cause mortality, reinfarction, coronary angiographies, and revascularizations in patients with MI diagnosed using hs-cTnT compared with those diagnosed using conventional troponins (cTn).

RESULTS - During the study period, 47,133 MIs were diagnosed using cTn and 40,746 using hs-cTnT. The rate of MI increased by 5% (95% CI: 0% to 10%) after the introduction of hs-cTnT. During 3.9 ± 2.8 years of follow-up, there were 33,492 deaths, with no difference in the risk of all-cause mortality (adjusted HR: 1.00; 95% CI: 0.97 to 1.02). There were, in total, 15,766 reinfarctions during 3.1 ± 2.3 years of follow-up, with the risk of reinfarction reduced by 11% in patients diagnosed using hs-cTnT (adjusted HR: 0.89; 95% CI: 0.86 to 0.91). The use of coronary angiographies (adjusted HR: 1.16; 95% CI: 1.14 to 1.18) and revascularizations (adjusted HR: 1.13; 95% CI: 1.11 to 1.15) increased in the hs-cTnT group.

CONCLUSIONS - In a nationwide cohort study including 87,879 patients with a first MI, the introduction of hs-cTnT was associated with an increased incidence of MI, although with no impact on survival. We also found a reduced risk of reinfarction alongside increased use of coronary angiographies and revascularizations.