CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Health Status After Transcatheter Versus Surgical Aortic Valve Replacement in Low-Risk Patients With Aortic Stenosis Transcatheter Aortic Valve Replacement During Pregnancy Comparison of newer generation self-expandable vs. balloon-expandable valves in transcatheter aortic valve implantation: the randomized SOLVE-TAVI trial Mechanisms of in-stent restenosis after drug-eluting stent implantation: intravascular ultrasound analysis Association of Effective Regurgitation Orifice Area to Left Ventricular End-Diastolic Volume Ratio With Transcatheter Mitral Valve Repair OutcomesA Secondary Analysis of the COAPT Trial Feasibility of Coronary Access and Aortic Valve Reintervention in Low-Risk TAVR Patients The Year in Cardiovascular Medicine 2020: Valvular Heart Disease: Discussing the Year in Cardiovascular Medicine for 2020 in the field of valvular heart disease is Professor Helmut Baumgartner and Dr Javier Bermejo. Mark Nicholls reports Five-Year Outcomes of Transcatheter or Surgical Aortic-Valve Replacement Baseline Characteristics and Risk Profiles of Participants in the ISCHEMIA Randomized Clinical Trial Risk of Coronary Obstruction and Feasibility of Coronary Access After Repeat Transcatheter Aortic Valve Replacement With the Self-Expanding Evolut Valve: A Computed Tomography Simulation Study

Clinical Trial 2018 Jun;11(6):859-867.

JOURNAL:JACC Cardiovasc Imaging. Article Link

Uncovered Culprit Plaque Ruptures in Patients With ST-Segment Elevation Myocardial Infarction Assessed by Optical Coherence Tomography and Intravascular Ultrasound With iMap

Hougaard M, Hansen HS, Thayssen P et al. Keywords: OCT; STEMI; plaque rupture

ABSTRACT


OBJECTIVES - This study assessed the incidence and course of healing of uncovered plaque ruptures (PR) following primary percutaneous coronary intervention.


BACKGROUND - The infarct-related occlusion is frequently located at the lesion site with maximum thrombus burden, whereas the culprit PR may be situated more proximally or distally.

METHODS - Uncovered PR in segments adjacent to the stent were identified by optical coherence tomography and intravascular ultrasound using iMap (Boston Scientific, Marlborough, Massachusetts) within 48 h and after 12 months. The percentages of necrotic core, fibrotic tissue, lipid tissue, and calcific tissue were determined.

RESULTS - Eleven uncovered PR were found in 10 of 77 patients (13.0%). Eight of these ruptures (10.4%) were identified as culprit and were located proximal to the stent. Two patients were treated before follow-up due to recurrent symptoms. After 12 months, 3 PR had healed incompletely without causing symptoms. The lumen area at the PR site was reduced (7.5 mm2 [interquartile range (IQR): 4.8 to 9.3 mm2] to 3.6 mm2 [IQR: 2.8 to 8.0 mm2]; p = 0.012). Proximal segments with uncovered PR had greater plaque volumes (62.1 mm3 [IQR: 50.2 to 83.6 mm3] vs. 38.7 mm3 [IQR: 29.6 to 47.6 mm3], respectively; p < 0.001), vessel volumes (110.7 mm3 [IQR: 92.3 to 128.1 mm3] vs. 76.0 mm3 [IQR: 63.8 to 100.3 mm3], respectively; p < 0.001), and greater percentages of necrotic core (34.0% [IQR: 29.0% to 44.5%] vs. 20.5% (IQR: 10.0% to 29.0%]; p < 0.001). Conversely, percentages of fibrotic tissue were lower (44.0% [IQR: 32.0% to 47.0%] vs. 56.0% [IQR: 46.0% to 66.0%]; p = 0.001), whereas no differences were found for lipid tissue and calcific tissue.

CONCLUSIONS - Uncovered culprit ruptures detected by optical coherence tomography were common following primary percutaneous coronary intervention and were found to be associated with significant lumen reduction during the healing process.

Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.