CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

North American Expert Review of Rotational Atherectomy Treating Bifurcation Lesions: The Result Overcomes the Technique Orbital atherectomy for the treatment of small (2.5mm) severely calcified coronary lesions: ORBIT II sub-analysis Pulmonary hypertension is associated with an increased incidence of NAFLD: A retrospective cohort study of 18,910 patients Comparison of 2 Different Drug-Coated Balloons in In-Stent Restenosis: The RESTORE ISR China Randomized Trial Pivotal trial to evaluate the safety and efficacy of the orbital atherectomy system in treating de novo, severely calcified coronary lesions (ORBIT II) Temporal changes in radial access use, associates and outcomes in patients undergoing PCI using rotational atherectomy between 2007 and 2014: results from the British Cardiovascular Intervention Society national database Right ventricular expression of NT-proBNP adds predictive value to REVEAL score in patients with pulmonary arterial hypertension Drug-Coated Balloon for De Novo Coronary Artery Disease: JACC State-of-the-Art Review Intravascular ultrasound enhances the safety of rotational atherectomy

Clinical Trial 2018 Jun;11(6):859-867.

JOURNAL:JACC Cardiovasc Imaging. Article Link

Uncovered Culprit Plaque Ruptures in Patients With ST-Segment Elevation Myocardial Infarction Assessed by Optical Coherence Tomography and Intravascular Ultrasound With iMap

Hougaard M, Hansen HS, Thayssen P et al. Keywords: OCT; STEMI; plaque rupture

ABSTRACT


OBJECTIVES - This study assessed the incidence and course of healing of uncovered plaque ruptures (PR) following primary percutaneous coronary intervention.


BACKGROUND - The infarct-related occlusion is frequently located at the lesion site with maximum thrombus burden, whereas the culprit PR may be situated more proximally or distally.

METHODS - Uncovered PR in segments adjacent to the stent were identified by optical coherence tomography and intravascular ultrasound using iMap (Boston Scientific, Marlborough, Massachusetts) within 48 h and after 12 months. The percentages of necrotic core, fibrotic tissue, lipid tissue, and calcific tissue were determined.

RESULTS - Eleven uncovered PR were found in 10 of 77 patients (13.0%). Eight of these ruptures (10.4%) were identified as culprit and were located proximal to the stent. Two patients were treated before follow-up due to recurrent symptoms. After 12 months, 3 PR had healed incompletely without causing symptoms. The lumen area at the PR site was reduced (7.5 mm2 [interquartile range (IQR): 4.8 to 9.3 mm2] to 3.6 mm2 [IQR: 2.8 to 8.0 mm2]; p = 0.012). Proximal segments with uncovered PR had greater plaque volumes (62.1 mm3 [IQR: 50.2 to 83.6 mm3] vs. 38.7 mm3 [IQR: 29.6 to 47.6 mm3], respectively; p < 0.001), vessel volumes (110.7 mm3 [IQR: 92.3 to 128.1 mm3] vs. 76.0 mm3 [IQR: 63.8 to 100.3 mm3], respectively; p < 0.001), and greater percentages of necrotic core (34.0% [IQR: 29.0% to 44.5%] vs. 20.5% (IQR: 10.0% to 29.0%]; p < 0.001). Conversely, percentages of fibrotic tissue were lower (44.0% [IQR: 32.0% to 47.0%] vs. 56.0% [IQR: 46.0% to 66.0%]; p = 0.001), whereas no differences were found for lipid tissue and calcific tissue.

CONCLUSIONS - Uncovered culprit ruptures detected by optical coherence tomography were common following primary percutaneous coronary intervention and were found to be associated with significant lumen reduction during the healing process.

Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.