CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Left Atrial Appendage Closure versus Non-Warfarin Oral Anticoagulation in Atrial Fibrillation: 4-Year Outcomes of PRAGUE-17 Frailty and Clinical Outcomes of Direct Oral Anticoagulants Versus Warfarin in Older Adults With Atrial Fibrillation: A Cohort Study Patent Foramen Ovale Attributable Cryptogenic Embolism With Thrombophilia Has Higher Risk for Recurrence and Responds to Closure Alcohol consumption, cardiac biomarkers, and risk of atrial fibrillation and adverse outcomes Role of endothelial dysfunction in determining angina after percutaneous coronary intervention: Learning from pathophysiology to optimize treatment Stretch-induced sarcoplasmic reticulum calcium leak is causatively associated with atrial fibrillation in pressure-overloaded hearts Systematic Review and Network Meta‐Analysis Comparing Bifurcation Techniques for Percutaneous Coronary Intervention Transcatheter Aortic Valve Implantation Represents an Anti-Inflammatory Therapy Via Reduction of Shear Stress-Induced, Piezo-1-Mediated Monocyte Activation Potential Candidates for Transcatheter Tricuspid Valve Intervention After Transcatheter Aortic Valve Replacement: Predictors and Prognosis Residual Shunt After Patent Foramen Ovale Closure and Long-Term Stroke Recurrence: A Prospective Cohort Study

Clinical Trial 2018 Jun;11(6):859-867.

JOURNAL:JACC Cardiovasc Imaging. Article Link

Uncovered Culprit Plaque Ruptures in Patients With ST-Segment Elevation Myocardial Infarction Assessed by Optical Coherence Tomography and Intravascular Ultrasound With iMap

Hougaard M, Hansen HS, Thayssen P et al. Keywords: OCT; STEMI; plaque rupture

ABSTRACT


OBJECTIVES - This study assessed the incidence and course of healing of uncovered plaque ruptures (PR) following primary percutaneous coronary intervention.


BACKGROUND - The infarct-related occlusion is frequently located at the lesion site with maximum thrombus burden, whereas the culprit PR may be situated more proximally or distally.

METHODS - Uncovered PR in segments adjacent to the stent were identified by optical coherence tomography and intravascular ultrasound using iMap (Boston Scientific, Marlborough, Massachusetts) within 48 h and after 12 months. The percentages of necrotic core, fibrotic tissue, lipid tissue, and calcific tissue were determined.

RESULTS - Eleven uncovered PR were found in 10 of 77 patients (13.0%). Eight of these ruptures (10.4%) were identified as culprit and were located proximal to the stent. Two patients were treated before follow-up due to recurrent symptoms. After 12 months, 3 PR had healed incompletely without causing symptoms. The lumen area at the PR site was reduced (7.5 mm2 [interquartile range (IQR): 4.8 to 9.3 mm2] to 3.6 mm2 [IQR: 2.8 to 8.0 mm2]; p = 0.012). Proximal segments with uncovered PR had greater plaque volumes (62.1 mm3 [IQR: 50.2 to 83.6 mm3] vs. 38.7 mm3 [IQR: 29.6 to 47.6 mm3], respectively; p < 0.001), vessel volumes (110.7 mm3 [IQR: 92.3 to 128.1 mm3] vs. 76.0 mm3 [IQR: 63.8 to 100.3 mm3], respectively; p < 0.001), and greater percentages of necrotic core (34.0% [IQR: 29.0% to 44.5%] vs. 20.5% (IQR: 10.0% to 29.0%]; p < 0.001). Conversely, percentages of fibrotic tissue were lower (44.0% [IQR: 32.0% to 47.0%] vs. 56.0% [IQR: 46.0% to 66.0%]; p = 0.001), whereas no differences were found for lipid tissue and calcific tissue.

CONCLUSIONS - Uncovered culprit ruptures detected by optical coherence tomography were common following primary percutaneous coronary intervention and were found to be associated with significant lumen reduction during the healing process.

Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.