CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Guideline‐Directed Medical Therapy for Patients With Heart Failure With Midrange Ejection Fraction: A Patient‐Pooled Analysis From the KorHF and KorAHF Registries Natriuretic Peptide-Guided Heart Failure Therapy After the GUIDE-IT Study Association of Abnormal Left Ventricular Functional Reserve With Outcome in Heart Failure With Preserved Ejection Fraction Short- versus long-term duration of dual-antiplatelet therapy after coronary stenting: a randomized multicenter trial Modifiable lifestyle factors and heart failure: A Mendelian randomization study Metabolic Interactions and Differences between Coronary Heart Disease and Diabetes Mellitus: A Pilot Study on Biomarker Determination and Pathogenesis Catastrophic catheter-induced coronary artery vasospasm successfully rescued using intravascular ultrasound imaging guidance Baseline Features of the VICTORIA (Vericiguat Global Study in Subjects With Heart Failure With Reduced Ejection Fraction) Trial Combined Tricuspid and Mitral Versus Isolated Mitral Valve Repair for Severe MR and TR: An Analysis From the TriValve and TRAMI Registries Coronary plaque redistribution after stent implantation is determined by lipid composition: A NIRS-IVUS analysis

Clinical Trial2018 Jun 21. [Epub ahead of print]

JOURNAL:Eur Heart J. Article Link

Japan-United States of America Harmonized Assessment by Randomized Multicentre Study of OrbusNEich's Combo StEnt (Japan-USA HARMONEE) study: primary results of the pivotal registration study of combined endothelial progenitor cell capture and drug-eluting stent in patients with ischaemic coronary disease and non-ST-elevation acute coronary syndrome

Saito S, Krucoff MW, Nakamura S et al. Keywords: DES; RCT; PCI; Endothelial progenitor cells; Japan

ABSTRACT


AIMSHarmonized Assessment by Randomized Multicentre Study of OrbusNEich's Combo StEnt (HARMONEE) (NCT02073565) was a randomized pivotal registration trial of the Combo stent, which combined sirolimus and an abluminal bioabsorbable polymer with a novel endoluminal anti-CD34+ antibody coating designed to capture endothelial progenitor cells (EPC) and promote percutaneous coronary intervention (PCI) site healing.


METHODS AND RESULTS - Clinically stabilized PCI subjects were randomized 1:1 to receive Combo or everolimus-eluting stents (EES). Between February 2014 and June 2016, 572 subjects with 675 coronary lesions underwent 1-year angiography and fractional flow reserve, with optical coherence tomography (OCT) in the first 140 patients. The primary clinical endpoint was non-inferior 1-year target vessel failure (TVF). The primary mechanistic endpoint of EPC capture activity was superior strut coverage by OCT. Target vessel failure occurred in 7.0% Combo (20/287) vs. 4.2% EES (12/285), a 2.8% [95% confidence interval (95% CI) -1.0%, 6.5%] difference, meeting the non-inferiority hypothesis (P = 0.02). There were no cardiac deaths, with one stent thrombosis observed in the EES group. Quantitative coronary angiography late loss with Combo was equivalent to EES. Optical coherence tomography strut coverage at 1 year was superior with Combo vs. EES [91.3% (95% CI 88.7%, 93.8%) vs. 74.8% (95% CI 70.0%, 79.6%), P < 0.001], with homogeneous tissue in 81.2% vs. 68.8%, respectively.

CONCLUSION - Combo stent demonstrated non-inferior 1-year TVF and late loss in a randomized comparison to EES, with superior strut-based tissue coverage by OCT as a surrogate of EPC capture technology activity.