CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Why and How to Measure Aortic Valve Calcification in Patients With Aortic Stenosis Transcatheter Aortic Valve Replacement During Pregnancy Use of IVUS guided coronary stenting with drug eluting stent: a systematic review and meta-analysis of randomized controlled clinical trials and high quality observational studies rhACE2 Therapy Modifies Bleomycin-Induced Pulmonary Hypertension via Rescue of Vascular Remodeling Comparison of the Efficacy and Safety Outcomes of Edoxaban in 8040 Women Versus 13 065 Men With Atrial Fibrillation in the ENGAGE AF-TIMI 48 Trial Comparison of plaque characteristics in narrowings with ST-elevation myocardial infarction (STEMI), non-STEMI/unstable angina pectoris and stable coronary artery disease (from the ADAPT-DES IVUS Substudy) Reduced Apolipoprotein M and Adverse Outcomes Across the Spectrum of Human Heart Failure Comprehensive intravascular ultrasound assessment of stent area and its impact on restenosis and adverse cardiac events in 403 patients with unprotected left main disease The Utility of Rapid Atrial Pacing Immediately Post-TAVR to Predict the Need for Pacemaker Implantation Transcatheter Aortic Valve Implantation Represents an Anti-Inflammatory Therapy Via Reduction of Shear Stress-Induced, Piezo-1-Mediated Monocyte Activation

Clinical Case StudyJune 2017, Volume 33, Issue 6, pp 807–813

JOURNAL:Int J Cardiovasc Imaging. Article Link

Intravascular ultrasound guidance of percutaneous coronary intervention in ostial chronic total occlusions: a description of the technique and procedural results

Ryan N1, Gonzalo N, Escaned J et al. Keywords: Chronic total occlusion; Intravascular ultrasound; Percutaneous coronary intervention

ABSTRACT

Inability to cross the lesion with a guidewire is the most common reason for failure in percutaneousrevascularization (PCI) of chronic total occlusions (CTOs). An ostial or stumpless CTO is an acknowledged challenge for CTO recanalization due to difficulty in successful wiring. IVUS imaging provides the opportunity to visualize the occluded vessel and to aid guidewire advancement. We review the value of this technique in a single-centre experience of CTO PCI. This series involves 22 patients who underwent CTO-PCI using IVUS guidance for stumpless CTO wiring at our institution. CTO operators with extensive IVUS experience in non-CTO cases carried out all procedures. Procedural and outcome data was prospectively entered into the institutional database and a retrospective analysis of clinical, angiographic and technical data performed. 17 (77%) of the 22 procedures were successful. The mean age was 59.8 ± 11.5 years, and 90.9% were male. The most commonly attempted lesions were located in the left anterior descending 36.4% (Soon et al. in J Intervent Cardiol 20(5):359-366, 2007) and Circumflex artery (LCx) 31.8% (Mollet et al. in Am J Cardiol 95(2):240-243, 2005). Mean JCTO score was 3.09 ± 0.75 (3.06 ± 0.68, 3.17 ± 0.98 in the successful and failed groups respectively p = 0.35). The mean contrast volume was 378.7 ml ± 114.7 (389.9 ml ± 130.5, 349.2 ml ± 52.2 p = 0.3 in the successful and failed groups respectively). There was no death, coronary artery bypass grafting or myocardial infarction requiring intervention in this series. When the success rates were analyzed taking into account the date of adoption of this technique, the learning curve had no significant impact on CTO-PCI success. This series describes a good success rate in IVUS guided stumpless wiring of CTOs in consecutive patients with this complex anatomical scenario.