The effect of complete percutaneous revascularisation with and without intravascular ultrasound guidance in the drugeluting stent era A new strategy for discontinuation of dual antiplatelet therapy: the RESET Trial (REal Safety and Efficacy of 3-month dual antiplatelet Therapy following Endeavor zotarolimus-eluting stent implantation) The Year in Cardiovascular Medicine 2020: Valvular Heart Disease: Discussing the Year in Cardiovascular Medicine for 2020 in the field of valvular heart disease is Professor Helmut Baumgartner and Dr Javier Bermejo. Mark Nicholls reports Intravascular ultrasound guidance improves clinical outcomes during implantation of both first- and second-generation drug-eluting stents: a meta-analysis Clinical Outcomes Following Intravascular Imaging-Guided Versus Coronary Angiography-Guided Percutaneous Coronary Intervention With Stent Implantation: A Systematic Review and Bayesian Network Meta-Analysis of 31 Studies and 17,882 Patients Cardiac and Kidney Benefits of Empagliflozin in Heart Failure Across the Spectrum of Kidney Function: Insights From EMPEROR-Reduced Economic and Quality-of-Life Outcomes of Natriuretic Peptide–Guided Therapy for Heart Failure Dual-antiplatelet treatment beyond 1 year after drug-eluting stent implantation (ARCTIC-Interruption): a randomised trial Ticagrelor Monotherapy Versus Dual-Antiplatelet Therapy After PCI: An Individual Patient-Level Meta-Analysis A volumetric intravascular ultrasound comparison of early drug-eluting stent thrombosis versus restenosis

Clinical Trial2014 Dec;10(8):916-23.

JOURNAL:Circulation. Article Link

Randomized study to evaluate sirolimus-eluting stents implanted at coronary bifurcation lesions

Colombo A, Moses JW, Morice MC et al. Keywords: coronary bifurcation lesion; sirolimus-eluting stent; restenosis

ABSTRACT


BACKGROUND - A sirolimus-eluting stent (Cypher, Cordis Corp) has been reported to markedly decrease restenosis in selected lesions; higher-risk lesions, including coronary bifurcations, have not been studied.


METHODS AND RESULTS - This prospective study evaluated the safety and efficacy of sirolimus-eluting stents for treatment of coronary bifurcation lesions. Patients were randomly assigned to either stenting of both branches (group A) or stenting of the main branch with provisional stenting of the side branch (SB) (group B). Eighty-five patients (86 lesions) were enrolled. There was 1 case of unsuccessful delivery of any device at the bifurcation site. Given the high crossover, more lesions were treated with 2 stents (n=63) than with stent/balloon (n=22). Clinical follow-up at 6 months was completed in all patients and angiographic follow-up in 53 patients in group A (85.5%) and 21 in group B (95.4%). One patient died suddenly 4.5 months after the procedure. There were 3 cases of stent thrombosis (3.5%). The total restenosis rate at 6 months was 25.7%, and it was not significantly different between the double-stenting (28.0%) and the provisional SB-stenting (18.7%) groups. Fourteen of the restenosis cases occurred at the ostium of the SB and were focal. Target lesion revascularization was performed in 7 cases; target vessel failure occurred in 15 cases (17.6%).

CONCLUSIONS - These results are an improvement compared with historical controls using bare metal stents. Restenosis at the SB remains a problem. At this time, no statement can be made regarding the most appropriate technique to use when treating bifurcations with the Cypher stent.