CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Ablation Versus Drug Therapy for Atrial Fibrillation in Heart Failure Results From the CABANA Trial Percutaneous Left Atrial Appendage Occlusion for Patients in Atrial Fibrillation Suboptimal for Warfarin Therapy: 5-year Results of the PLAATO (Percutaneous Left Atrial Appendage Transcatheter Occlusion) Study Does pulsed field ablation regress over time? A quantitative temporal analysis of pulmonary vein isolation Endoplasmic reticulum stress in doxorubicin-induced cardiotoxicity may be therapeutically targeted by natural and chemical compounds: A review The management of secondary mitral regurgitation in patients with heart failure: a joint position statement from the Heart Failure Association (HFA), European Association of Cardiovascular Imaging (EACVI), European Heart Rhythm Association (EHRA), and European Association of Percutaneous Cardiovascular Interventions (EAPCI) of the ESC Prospective Evaluation of Transseptal TMVR for Failed Surgical Bioprostheses: MITRAL Trial Valve-in-Valve Arm 1-Year Outcomes Current Status and Future Prospects of Transcatheter Mitral Valve Replacement: JACC State-of-the-Art Review Single direct oral anticoagulant therapy in stable patients with atrial fibrillation beyond 1 year after coronary stent implantation 2015 ACC/HRS/SCAI Left Atrial Appendage Occlusion Device Societal Overview Strain-Guided Management of Potentially Cardiotoxic Cancer Therapy

Clinical Trial2014 Dec;10(8):916-23.

JOURNAL:Circulation. Article Link

Randomized study to evaluate sirolimus-eluting stents implanted at coronary bifurcation lesions

Colombo A, Moses JW, Morice MC et al. Keywords: coronary bifurcation lesion; sirolimus-eluting stent; restenosis

ABSTRACT


BACKGROUND - A sirolimus-eluting stent (Cypher, Cordis Corp) has been reported to markedly decrease restenosis in selected lesions; higher-risk lesions, including coronary bifurcations, have not been studied.


METHODS AND RESULTS - This prospective study evaluated the safety and efficacy of sirolimus-eluting stents for treatment of coronary bifurcation lesions. Patients were randomly assigned to either stenting of both branches (group A) or stenting of the main branch with provisional stenting of the side branch (SB) (group B). Eighty-five patients (86 lesions) were enrolled. There was 1 case of unsuccessful delivery of any device at the bifurcation site. Given the high crossover, more lesions were treated with 2 stents (n=63) than with stent/balloon (n=22). Clinical follow-up at 6 months was completed in all patients and angiographic follow-up in 53 patients in group A (85.5%) and 21 in group B (95.4%). One patient died suddenly 4.5 months after the procedure. There were 3 cases of stent thrombosis (3.5%). The total restenosis rate at 6 months was 25.7%, and it was not significantly different between the double-stenting (28.0%) and the provisional SB-stenting (18.7%) groups. Fourteen of the restenosis cases occurred at the ostium of the SB and were focal. Target lesion revascularization was performed in 7 cases; target vessel failure occurred in 15 cases (17.6%).

CONCLUSIONS - These results are an improvement compared with historical controls using bare metal stents. Restenosis at the SB remains a problem. At this time, no statement can be made regarding the most appropriate technique to use when treating bifurcations with the Cypher stent.