CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Randomized study on simple versus complex stenting of coronary artery bifurcation lesions: the Nordic bifurcation study Contemporary techniques in percutaneous coronary intervention for bifurcation lesions Drug-Coated Balloons for Coronary Artery Disease: Third Report of the International DCB Consensus Group Treatment of Very Small De Novo Coronary Artery Disease With 2.0 mm Drug-Coated Balloons Showed 1-Year Clinical Outcome Comparable With 2.0 mm Drug-Eluting Stents Influence of Local Myocardial Damage on Index of Microcirculatory Resistance and Fractional Flow Reserve in Target and Nontarget Vascular Territories in a Porcine Microvascular Injury Model Adaptive development of concomitant secondary mitral and tricuspid regurgitation after transcatheter aortic valve replacement Optical Coherence Tomography–Defined Plaque Vulnerability in Relation to Functional Stenosis Severity and Microvascular Dysfunction Long-term efficacy and safety of drug-coated balloons versus drug-eluting stents for small coronary artery disease (BASKET-SMALL 2): 3-year follow-up of a randomised, non-inferiority trial Clinical and angiographic outcomes of coronary dissection after paclitaxel-coated balloon angioplasty for small vessel coronary artery disease Drug-Coated Balloons: A Safe and Effective Alternative to Drug-Eluting Stents in Small Vessel Coronary Artery Disease

Clinical Trial2014 Dec;10(8):916-23.

JOURNAL:Circulation. Article Link

Randomized study to evaluate sirolimus-eluting stents implanted at coronary bifurcation lesions

Colombo A, Moses JW, Morice MC et al. Keywords: coronary bifurcation lesion; sirolimus-eluting stent; restenosis

ABSTRACT


BACKGROUNDA sirolimus-eluting stent (Cypher, Cordis Corp) has been reported to markedly decrease restenosis in selected lesions; higher-risk lesions, including coronary bifurcations, have not been studied.


METHODS AND RESULTS - This prospective study evaluated the safety and efficacy of sirolimus-eluting stents for treatment of coronary bifurcation lesions. Patients were randomly assigned to either stenting of both branches (group A) or stenting of the main branch with provisional stenting of the side branch (SB) (group B). Eighty-five patients (86 lesions) were enrolled. There was 1 case of unsuccessful delivery of any device at the bifurcation site. Given the high crossover, more lesions were treated with 2 stents (n=63) than with stent/balloon (n=22). Clinical follow-up at 6 months was completed in all patients and angiographic follow-up in 53 patients in group A (85.5%) and 21 in group B (95.4%). One patient died suddenly 4.5 months after the procedure. There were 3 cases of stent thrombosis (3.5%). The total restenosis rate at 6 months was 25.7%, and it was not significantly different between the double-stenting (28.0%) and the provisional SB-stenting (18.7%) groups. Fourteen of the restenosis cases occurred at the ostium of the SB and were focal. Target lesion revascularization was performed in 7 cases; target vessel failure occurred in 15 cases (17.6%).

CONCLUSIONS - These results are an improvement compared with historical controls using bare metal stents. Restenosis at the SB remains a problem. At this time, no statement can be made regarding the most appropriate technique to use when treating bifurcations with the Cypher stent.