Cardiac surgery following transcatheter aortic valve replacement Regional Heterogeneity in the Coronary Vascular Response in Women With Chest Pain and Nonobstructive Coronary Artery Disease Computed tomography angiography-derived extracellular volume fraction predicts early recovery of left ventricular systolic function after transcatheter aortic valve replacement The role of integrated backscatter intravascular ultrasound in characterizing bare metal and drug-eluting stent restenotic neointima as compared to optical coherence tomography Attenuated plaque detected by intravascular ultrasound: clinical, angiographic, and morphologic features and post-percutaneous coronary intervention complications in patients with acute coronary syndromes Reduced Leaflet Motion after Transcatheter Aortic-Valve Replacement Decline in Left Ventricular Ejection Fraction During Follow-Up in Patients With Severe Aortic Stenosis Associations between Blood Lead Levels and Coronary Artery Stenosis Measured Using Coronary Computed Tomography Angiography

Original ResearchVolume 75, Issue 8, March 2020

JOURNAL:J Am Coll Cardiol. Article Link

Long-Term Outcomes of Anticoagulation for Bioprosthetic Valve Thrombosis

I Petrescu, AC Egbe, F Ionescu et al. Keywords: anticoagulation; bioprosthetic valve thrombosis; prosthetic valve failure

ABSTRACT


BACKGROUND - Early in the prevention and treatment of bioprosthetic valve thrombosis (BPVT), anticoagulation is effective, but the long-term outcome after BPVT is unknown.

 

OBJECTIVES - The goal of this study was to assess the long-term outcomes of patients with BPVT treated with anticoagulation.

 

METHODS - This analysis was a matched cohort study of patients treated with warfarin for suspected BPVT at the Mayo Clinic between 1999 and 2017.

 

RESULTS - A total of 83 patients treated with warfarin for suspected BPVT (age 57 ± 18 years; 45 men [54%]) were matched to 166 control subjects; matching was performed according to age, sex, year of implantation, and prosthesis type and position. Echocardiography normalized in 62 patients (75%) within 3 months (interquartile range [IQR]: 1.5 to 6 months) of anticoagulation; 21 patients (25%) did not respond to warfarin. Median follow-up after diagnosis was 34 months (IQR: 17 to 54 months). There was no difference in the primary composite endpoint between the patients with BPVT and the matched control subjects (log-rank test, p = 0.79), but the former did have a significantly higher rate of major bleeding (12% vs. 2%; p < 0.0001). BPVT recurred (re-BPVT) in 14 (23%) responders after a median of 23 months (IQR: 11 to 39 months); all but one re-BPVT patient responded to anticoagulant therapy. Patients with BPVT had a higher probability of valve re-replacement (68% vs. 24% at 10 yearspost-BPVT; log-rank test, p < 0.001).

 

CONCLUSIONS - BPVT was associated with re-BPVT and early prosthetic degeneration in a significant number of patients. Indefinite warfarin anticoagulation should be considered after a confirmed BPVT episode, but this strategy must be balanced against an increased risk of bleeding.