Outcomes of procedural complications in transfemoral transcatheter aortic valve replacement Effect of Ticagrelor Monotherapy vs Ticagrelor With Aspirin on Major Bleeding and Cardiovascular Events in Patients With Acute Coronary Syndrome: The TICO Randomized Clinical Trial Use of the Instantaneous Wave-free Ratio or Fractional Flow Reserve in PCI Prognostic value of fibrinogen in patients with coronary artery disease and prediabetes or diabetes following percutaneous coronary intervention: 5-year findings from a large cohort study High-Risk Coronary Plaque Regression After Intensive Lifestyle Intervention in Nonobstructive Coronary Disease: A Randomized Study Impaired Retinal Microvascular Function Predicts Long-Term Adverse Events in Patients with Cardiovascular Disease Assessment Of Proximal Left Anterior Descending Artery Size By Intravascular Ultrasound For Optimal Stent Sizing The sinus venosus contributes to coronary vasculature through VEGFC-stimulated angiogenesis

Original Research2018 Feb 15;253:55-60.

JOURNAL:Int J Cardiol. Article Link

Correlation between frequency-domain optical coherence tomography and fractional flow reserve in angiographically-intermediate coronary lesions

Burzotta F, Nerla R, Hill J et al. Keywords: Fractional flow reserve; Intermediate coronary lesions; Optical coherence tomography

ABSTRACT


BACKGROUND - The decision-making process of patients with angiographically-intermediate coronary lesions (ICL) is clinically challenging and may benefit from adjunctive invasive techniques. Fractional-flow-reserve (FFR) represents the gold standard to evaluate ICL but frequency-domain optical-coherence-tomography (OCT) is a novel, promising, high resolution coronary imaging technique, which allows physiopathologic assessment of coronary plaque. We investigated the possible relation between OCT and FFR in selected ICL patients.


METHODS - Stable or unstable patients with ICL who underwent both FFR and OCT assessment at two large tertiary centers were retrospectively enrolled. FFR was performed according to standard methodology. OCT images were (on blind to clinical and FFR results) analyzed to assess minimal lumen area (MLA), percentage area stenosis (AS), thrombus and plaque ulceration.


RESULTS - Forty patients were identified (62±10years, 93% symptomatic, 35% acute presentation, 93% left-anterior-descending artery ICL). Percentage diameter stenosis at quantitative coronary angiography was 40±12% and FFR was 0.85±0.07. MLA (p=0.009), AS (p<0.001) and plaque ulceration (p=0.02) were significantly associated with FFR values. An integrated assessment of AS (≥ or <70%), MLA (≥ or <2.5mm2) and presence or absence of thrombus and plaque ulceration was found to have the potential to accurately (sensitivity 91%, specificity 93%) predict FFR results.


CONCLUSION - In patients with ICL, a combination of different OCT parameters may help predict FFR results. These findings suggest that only a comprehensive assessment of lesion features by OCT can allow an accurate prediction of lesion severity assessed by FFR.