CBS 2019
CBSMD教育中心
中 文

Scientific Library

Abstract

Recommended Article

5-Year Outcomes After TAVR With Balloon-Expandable Versus Self-Expanding Valves: Results From the CHOICE Randomized Clinical Trial Comparison of Accuracy of One-Use Methods for Calculating Fractional Flow Reserve by Intravascular Optical Coherence Tomography to That Determined by the Pressure-Wire Method Long-Term Clinical Outcomes of Final Kissing Ballooning in Coronary Bifurcation Lesions Treated With the 1-Stent Technique: Results From the COBIS II Registry (Korean Coronary Bifurcation Stenting Registry) Safety of intermediate left main stenosis revascularization deferral based on fractional flow reserve and intravascular ultrasound: A systematic review and meta-regression including 908 deferred left main stenosis from 12 studies Study of Two Dose Regimens of Ticagrelor Compared with Clopidogrel in Patients Undergoing Percutaneous Coronary Intervention for Stable Coronary Artery Disease (STEEL-PCI) Combined Tricuspid and Mitral Versus Isolated Mitral Valve Repair for Severe MR and TR: An Analysis From the TriValve and TRAMI Registries Clopidogrel Pharmacogenetics: State-of-the-Art Review and the TAILOR-PCI Study Extended antiplatelet therapy with clopidogrel alone versus clopidogrel plus aspirin after completion of 9- to 12-month dual antiplatelet therapy for acute coronary syndrome patients with both high bleeding and ischemic risk. Rationale and design of the OPT-BIRISK double-blinded, placebo-controlled randomized trial

Clinical TrialVolume 13, Issue 9, May 2020

JOURNAL:JACC: Cardiovascular Interventions Article Link

5-Year Outcomes After TAVR With Balloon-Expandable Versus Self-Expanding Valves: Results From the CHOICE Randomized Clinical Trial

Mohamed Abdel-Wahab, M Landt, Franz-Josef Neumann Keywords: aortic stenosis; balloon-expandable; durability; self-expanding; TAVR

ABSTRACT


OBJECTIVES -The purpose of this study was to evaluate clinical and echocardiographic outcome data of the CHOICE (Randomized Comparison of Transcatheter Heart Valves in High Risk Patients with Severe Aortic Stenosis: Medtronic CoreValve Versus Edwards SAPIEN XT) trial at 5 years.


BACKGROUND -  The CHOICE trial was designed to compare device performance of a balloon-expandable (BE) transcatheter heart valve (THV) versus a self-expanding (SE) THV.


METHODS - The CHOICE trial is an investigator-initiated trial that randomized 241 high-risk patients with severe symptomatic aortic stenosis and an anatomy suitable for treatment with both BE and SE THVs to transfemoral transcatheter aortic valve replacement with either device. The primary endpoint was device success. Patients were followed up to 5 years, with assessment of clinical outcomes, and echocardiographic evaluation of valve function and THV durability.


RESULTS - After 5 years, there were no statistically significant differences between BE and SE valves in the cumulative incidence of death from any cause (53.4% vs. 47.6%; p = 0.38), death from cardiovascular causes (31.6% vs. 21.5%; p = 0.12), all strokes (17.5% vs. 16.5%; p = 0.73), and repeat hospitalization for heart failure (28.9% vs. 22.5%; p = 0.75). SE patients had larger prosthetic valve area (1.6 ± 0.5 cm2 vs. 1.9 ± 0.5 cm2; p = 0.02) with a lower mean transprosthetic gradient (12.2 ± 8.7 mm Hg vs. 6.9 ± 2.7 mm Hg; p = 0.001) at 5 years. No differences were observed in the rates of paravalvular regurgitation. Clinical valve thrombosis occurred in 7 BE patients (7.3%) and 1 SE patient (0.8%; p = 0.06), and moderate or severe structural valve deterioration in 6 BE patients (6.6%) and no SE patient (0%; p = 0.018). The rate of bioprosthetic valve failure was low and not significantly different between both groups (4.1% vs. 3.4%; p = 0.63).


CONCLUSIONS -  Five-year follow-up of patients in the CHOICE trial revealed clinical outcomes after transfemoral transcatheter aortic valve replacement with early-generation BE and SE valves that were not statistically significantly different, with limited statistical power. Forward flow hemodynamics were significantly better with the SE valve. Moderate or severe structural valve deterioration was uncommon but occurred more frequently with the BE valve. (A Comparison of Transcatheter Heart Valves in High Risk Patients With Severe Aortic Stenosis: The CHOICE Trial [CHOICE]; NCT01645202)