CBS 2019
CBSMD教育中心
English

左主干支架

科研文章

荐读文献

Randomized Trial of Stents Versus Bypass Surgery for Left Main Coronary Artery Disease: 5-Year Outcomes of the PRECOMBAT Study Complex PCI procedures: challenges for the interventional cardiologist Sex differences in left main coronary artery stenting: Different characteristics but similar outcomes for women compared with men Percutaneous Coronary Intervention Using Drug-Eluting Stents Versus Coronary Artery Bypass Grafting for Unprotected Left Main Coronary Artery Stenosis: A Meta-Analysis of Randomized Trials Left Main Percutaneous Coronary Intervention Versus Coronary Artery Bypass Grafting in Patients With Prior Cerebrovascular Disease: Results From the EXCEL Trial Impact of coronary anatomy and stenting technique on long-term outcome after drug-eluting stent implantation for unprotected left main coronary artery disease Clinical and angiographic outcomes of patients treated with everolimus-eluting stents or first-generation Paclitaxel-eluting stents for unprotected left main disease Comparison of Outcomes of Percutaneous Coronary Intervention on Native Coronary Arteries Versus on Saphenous Venous Aorta Coronary Conduits in Patients With Low Left Ventricular Ejection Fraction and Impella Device Implantation Achieved or Attempted (from the PROTECT II Randomized Trial and the cVAD Registry) Revascularization in Patients With Left Main Coronary Artery Disease and Left Ventricular Dysfunction Expansion or contraction of stenting in coronary artery disease?

Review Article18 July 2017, [Epub ahead of print]

JOURNAL:Lancet Article Link

2-year outcomes with the Absorb bioresorbable scaffold for treatment of coronary artery disease: a systematic review and meta-analysis of seven randomised trials with an individual patient data substudy

Z.A. Ali; P.W. Serruys; G.W. Stone et al Keywords: Absorb bioresorbable scaffold, individual patient

ABSTRACT


Background - Bioresorbable vascular scaffolds (BVS) offer the potential to improve long-term outcomes of percutaneous coronary intervention after their complete bioresorption. Randomised trials have shown non-inferiority between BVS and metallic drug-eluting stents at 1 year in composite safety and effectiveness outcomes, although some increases in rates of target vessel-related myocardial infarction and device thrombosis were identified. Outcomes of BVS following the first year after implantation are unknown. We sought to ascertain whether BVS are as safe and effective as drug-eluting stents within 2 years after implantation and between 1 and 2 years.


Methods - We did a systematic review and meta-analysis of randomised trials in which patients were randomly assigned to everolimus-eluting Absorb BVS or metallic everolimus-eluting stents (EES) and followed up for at least 2 years. We searched MEDLINE, the Cochrane database, TCTMD, ClinicalTrials.gov, Clinical Trial Results, CardioSource, and abstracts and presentations from major cardiovascular meetings up to April 1, 2017, to identify relevant studies. The primary efficacy outcome measure was the device-oriented composite endpoint (cardiac mortality, target vessel-related myocardial infarction, or ischaemia-driven target lesion revascularisation) and the primary safety outcome measure was definite or probable device thrombosis. Individual patient data from the four ABSORB trials were used for landmark and subgroup analysis and multivariable modelling.


Findings - We identified seven randomised trials in which 5583 patients were randomly assigned to Absorb BVS (n=3261) or metallic EES (n=2322) and followed up for 2 years. BVS had higher 2-year relative risks of the device-oriented composite endpoint than did EES (9.4% [304 of 3217] vs 7.4% [169 of 2299]; relative risk [RR] 1.29 [95% CI 1.08-1.56], p=0.0059). These differences were driven by increased rates of target vessel-related myocardial infarction (5.8% [187 of 3218] vs 3.2% [74 of 2299]; RR 1.68 [95% CI 1.29-2.19], p=0.0003) and ischaemia-driven target lesion revascularisation (5.3% [169 of 3217] vs 3.9% [90 of 2300]; 1.40 [1.09-1.80], p=0.0090) with BVS, with non-significant differences in cardiac mortality. The cumulative 2-year incidence of device thrombosis was higher with BVS than with EES (2.3% [73 of 3187] vs 0.7% [16 of 2281]; RR 3.35 [95% CI 1.96-5.72], p<0.0001). Landmark analysis between 1 and 2 years also showed higher rates of the device-oriented composite endpoint (3.3% [69 of 2100] vs 1.9% [23 of 1193]; RR 1.64 [95% CI 1.03-2.61], p=0.0376) and device thrombosis (0.5% [11 of 2085] vs none [0 of 1183], p<0.0001) in BVS-treated patients than in EES-treated patients.


Interpretation - BVS was associated with increased rates of composite device-oriented adverse events and device thrombosis cumulatively at 2 years and between 1 and 2 years of follow-up compared with EES.