Long-Term Outcomes of Anticoagulation for Bioprosthetic Valve Thrombosis Clinical impact of conduction disturbances in transcatheter aortic valve replacement recipients: a systematic review and meta-analysis Randomized Evaluation of TriGuard 3 Cerebral Embolic Protection After Transcatheter Aortic Valve Replacement: REFLECT II Left Ventricular Rapid Pacing Via the Valve Delivery Guidewire in Transcatheter Aortic Valve Replacement Balloon Aortic Valvuloplasty as a Bridge to Aortic Valve Replacement: A Contemporary Nationwide Perspective Rationale and design of a randomized clinical trial comparing safety and efficacy of Myval transcatheter heart valve versus contemporary transcatheter heart valves in patients with severe symptomatic aortic valve stenosis: the LANDMARK trial Relationship Between Hospital Surgical Aortic Valve Replacement Volume and Transcatheter Aortic Valve Replacement Outcomes Comparison of Early Surgical or Transcatheter Aortic Valve Replacement Versus Conservative Management in Low-Flow, Low-Gradient Aortic Stenosis Using Inverse Probability of Treatment Weighting: Results From the TOPAS Prospective Observational Cohort Study 2020 ACC Expert Consensus Decision Pathway on Management of Conduction Disturbances in Patients Undergoing Transcatheter Aortic Valve Replacement A Report of the American College of Cardiology Solution Set Oversight Committee Transcatheter Versus Surgical Aortic Valve Replacement in Low-Risk Patients

Clinical TrialJanuary 9, 2020

JOURNAL:N Engl J Med. Article Link

Reduced Leaflet Motion after Transcatheter Aortic-Valve Replacement

OD Backer, GD Dangas, the GALILEO-4D Investigators et al. Keywords: leaflet thrombosis substudy; rivaroxaban vs clopidogrel; post TAVR

ABSTRACT


BACKGROUND - Subclinical leaflet thickening and reduced leaflet motion of bioprosthetic aortic valves have been documented by four-dimensional computed tomography (CT). Whether anticoagulation can reduce these phenomena after transcatheter aortic-valve replacement (TAVR) is not known.

 

METHODS - In a substudy of a large randomized trial, we randomly assigned patients who had undergone successful TAVR and who did not have an indication for long-term anticoagulation to a rivaroxaban-based antithrombotic strategy (rivaroxaban [10 mg] plus aspirin [75 to 100 mg] once daily) or an antiplatelet-based strategy (clopidogrel [75 mg] plus aspirin [75 to 100 mg] once daily). Patients underwent evaluation by four-dimensional CT at a mean (±SD) of 90±15 days after randomization. The primary end point was the percentage of patients with at least one prosthetic valve leaflet with grade 3 or higher motion reduction (i.e., involving >50% of the leaflet). Leaflet thickening was also assessed.

 

RESULTS - A total of 231 patients were enrolled. At least one prosthetic valve leaflet with grade 3 or higher motion reduction was found in 2 of 97 patients (2.1%) who had scans that could be evaluated in the rivaroxaban group, as compared with 11 of 101 (10.9%) in the antiplatelet group (difference, 8.8 percentage points; 95% confidence interval [CI], 16.5 to 1.9; P=0.01). Thickening of at least one leaflet was observed in 12 of 97 patients (12.4%) in the rivaroxaban group and in 33 of 102 (32.4%) in the antiplatelet group (difference, 20.0 percentage points; 95% CI, 30.9 to 8.5). In the main trial, the risk of death or thromboembolic events and the risk of life-threatening, disabling, or major bleeding were higher with rivaroxaban (hazard ratios of 1.35 and 1.50, respectively).

 

CONCLUSIONS - In a substudy of a trial involving patients without an indication for long-term anticoagulation who had undergone successful TAVR, a rivaroxaban-based antithrombotic strategy was more effective than an antiplatelet-based strategy in preventing subclinical leaflet-motion abnormalities. However, in the main trial, the rivaroxaban-based strategy was associated with a higher risk of death or thromboembolic complications and a higher risk of bleeding than the antiplatelet-based strategy. (Funded by Bayer; GALILEO-4D ClinicalTrials.gov number, NCT02833948.)