Minimalist transcatheter aortic valve replacement: The new standard for surgeons and cardiologists using transfemoral access? Computed tomography angiography-derived extracellular volume fraction predicts early recovery of left ventricular systolic function after transcatheter aortic valve replacement Impact of Pre-Existing and New-Onset Atrial Fibrillation on Outcomes After Transcatheter Aortic Valve Replacement Determinants and Impact of Heart Failure Readmission Following Transcatheter Aortic Valve Replacement Coronary Protection to Prevent Coronary Obstruction During TAVR: A Multicenter International Registry Cardiac surgery following transcatheter aortic valve replacement Impact of Incomplete Coronary Revascularization on Late Ischemic and Bleeding Events after Transcatheter Aortic Valve Replacement Prognostic Value of Computed Tomography-Derived Extracellular Volume in TAVR Patients With Low-Flow Low-Gradient Aortic Stenosis Coronary Access After TAVR With a Self-Expanding Bioprosthesis: Insights From Computed Tomography A Controlled Trial of Rivaroxaban After Transcatheter Aortic-Valve Replacement

Original ResearchVolume 13, Issue 6, March 2020

JOURNAL:JACC Cardiovasc Interv. Article Link

Coronary Protection to Prevent Coronary Obstruction During TAVR: A Multicenter International Registry

T Palmerini, T Chakravarty, F Saia et al. Keywords: coronary obstruction; stent thrombosis; TAVR

ABSTRACT


OBJECTIVES - The aim of this study was to investigate the safety and efficacy of coronary protection by preventive coronary wiring and stenting across the coronary ostia in patients at high risk for coronary obstruction after transcatheter aortic valve replacement (TAVR).

 

BACKGROUND - Coronary obstruction following TAVR is a life-threatening complication with high procedural and short-term mortality.

 

METHODS - Data were collected retrospectively from a multicenter international registry between April 2011 and February 2019.

 

RESULTS - Among 236 patients undergoing coronary protection with preventive coronary wiring, 143 had eventually stents implanted across the coronary ostia after valve deployment. At 3-year follow-up, rates of cardiac death were 7.8% in patients receiving stents and 15.7% in those not receiving stents (adjusted hazard ratio: 0.42; 95% confidence interval: 0.14 to 1.28; p = 0.13). There were 2 definite stent thromboses (0.9%) in patients receiving stents, both occurring after TAVR in “valve-in-valve” procedures. In patients not receiving stents, there were 4 delayed coronary occlusions (DCOs) (4.3%), occurring from 5 min to 6 h after wire removal. Three cases occurred in valve-in-valve procedures and 1 in a native aortic valve procedure. Distance between the virtual transcatheter valve and the protected coronary ostia <4 mm was present in 75.0% of patients with DCO compared with 30.4% of patients without DCO (p = 0.19).

 

CONCLUSIONS - In patients undergoing TAVR at high risk for coronary obstruction, preventive stent implantation across the coronary ostia is associated with good mid-term survival rates and low rates of stent thrombosis. Patients undergoing coronary protection with wire only have a considerable risk for DCO.