Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients Early Versus Standard Discharge After Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis Preventing Coronary Obstruction During Transcatheter Aortic Valve Replacement From Computed Tomography to BASILICA Surgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients Transcatheter Laceration of Aortic Leaflets to Prevent Coronary Obstruction During Transcatheter Aortic Valve Replacement: Concept to First-in-Human A prospective, randomised trial of transapical transcatheter aortic valve implantation vs. surgical aortic valve replacement in operable elderly patients with aortic stenosis: the STACCATO trial Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Severe Aortic Valve Stenosis: 1-Year Results From the All-Comers NOTION Randomized Clinical Trial Comparative Accuracy of Focused Cardiac Ultrasonography and Clinical Examination for Left Ventricular Dysfunction and Valvular Heart Disease: A Systematic Review and Meta-analysis

Clinical Trial2021 Mar 8;14(5):515-527.

JOURNAL:JACC Cardiovasc Interv. Article Link

Randomized Evaluation of TriGuard 3 Cerebral Embolic Protection After Transcatheter Aortic Valve Replacement: REFLECT II

TM Nazif, J Moses, REFLECT II Trial Investigators et al. Keywords: cerebral embolic protection; TAVR; RCT

ABSTRACT

OBJECTIVES - The REFLECT II (Randomized Evaluation of TriGuard 3 Cerebral Embolic Protection After Transcatheter Aortic Valve Implantation) trial was designed to investigate the safety and efficacy of the TriGUARD 3 (TG3) cerebral embolic protection in patients undergoing transcatheter aortic valve replacement.

 

BACKGROUND - Cerebral embolization occurs frequently following transcatheter aortic valve replacement and procedure-related ischemic stroke occurs in 2% to 6% of patients at 30 days. Whether cerebral protection with TriGuard 3 is safe and effective in reducing procedure-related cerebral injury is not known.

 

METHODS - This prospective, multicenter, single-blind, 2:1 randomized (TG3 vs. no TG3) study was designed to enroll up to 345 patients. The primary 30-day safety endpoint (Valve Academic Research Consortium-2 defined) was compared with a performance goal (PG). The primary hierarchical composite efficacy endpoint (including death or stroke at 30 days, National Institutes of Health Stroke Scale score worsening in hospital, and cerebral ischemic lesions on diffusion-weighted magnetic resonance imaging at 2 to 5 days) was compared using the Finkelstein-Schoenfeld method.

 

RESULTS - REFLECT II enrolled 220 of the planned 345 patients (63.8%), including 41 roll-in and 179 randomized patients (121 TG3 and 58 control subjects) at 18 US sites. The sponsor closed the study early after the U.S. Food and Drug Administration recommended enrollment suspension for unblinded safety data review. The trial met its primary safety endpoint compared with the PG (15.9% vs. 34.4% (p < 0.0001). The primary hierarchal efficacy endpoint at 30 days was not met (mean scores [higher is better]: 8.58 TG3 vs. 8.08 control; p = 0.857). A post hoc diffusion-weighted magnetic resonance imaging analysis of per-patient total lesion volume above incremental thresholds showed numeric reductions in total lesion volume >500 mm3 (9.7%) and >1,000 mm3 (44.5%) in the TG3 group, which were more pronounced among patients with full TG3 coverage: 51.1% (>500 mm3) and 82.9% (>1,000 mm3).

 

CONCLUSIONS - The REFLECT II trial demonstrated that the TG3 was safe compared with a historical PG but did not meet its pre-specified primary superiority efficacy endpoint.