CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

1-Year Outcomes of Delayed Versus Immediate Intervention in Patients With Transient ST-Segment Elevation Myocardial Infarction Accuracy of Fractional Flow Reserve Derived From Coronary Angiography Expansion or contraction of stenting in coronary artery disease? Differential prognostic effect of intravascular ultrasound use according to implanted stent length Transcatheter Aortic Valve Replacement: Role of Multimodality Imaging in Common and Complex Clinical Scenarios Nonculprit Lesion Plaque Morphology in Patients With ST-Segment–Elevation Myocardial Infarction: Results From the COMPLETE Trial Optical Coherence Tomography Substudys Association of Sustained Blood Pressure Control with Multimorbidity Progression Among Older Adults Differential Impact of Heart Failure With Reduced Ejection Fraction on Men and Women Stress Echocardiography and PH: What Do the Findings Mean? Comparison of Outcomes of Percutaneous Coronary Intervention on Native Coronary Arteries Versus on Saphenous Venous Aorta Coronary Conduits in Patients With Low Left Ventricular Ejection Fraction and Impella Device Implantation Achieved or Attempted (from the PROTECT II Randomized Trial and the cVAD Registry)

Clinical TrialSeptember 2019

JOURNAL:JACC Cardiovasc Interv. Article Link

Effect of Intravascular Ultrasound-Guided Drug-Eluting Stent Implantation: Five-Year Follow-Up of the IVUS-XPL Randomized Trial

SJ Hong, GS Mintz, the IVUS-XPL Investigators. Keywords: IVUS guidance superior to angiography guidance; MACE; long-term follow-up; long lesions

ABSTRACT


OBJECTIVES - The goal of this study was to evaluate whether the beneficial effect of use of intravascular ultrasound (IVUS) is sustained for long-term follow-up.

 

BACKGROUND - The use of IVUS promoted favorable 1-year clinical outcome in the IVUS-XPL trial. It is not known, however, whether this effect is sustained for long-term follow-up.

 

METHODS - The IVUS-XPL trial randomized 1,400 patients with long coronary lesions (implanted stent length ≥28mm) to receive IVUS- (n=700) or angiography-guided (n=700) everolimus-eluting stent implantation. Five-year clinical outcomes were investigated in patients who completed the original trial. Primary outcome was the composite of major adverse cardiac events, including cardiac death, target lesion-related myocardial infarction, or ischemia-driven target lesion revascularization at 5 years, analyzed by intention-to-treat.

 

RESULTS - Five-year follow-up was completed in 1,183 patients (85%). Major adverse cardiac events at 5 years occurred in 36 patients (5.6%) receiving IVUS-guidance and in 70 patients (10.7%) receiving angiography-guidance (hazard ratio [HR]=0.50, 95% confidence interval [CI]=0.34−0.75, P=0.001). The difference was mainly driven by a lower risk of target lesion revascularization (31 [4.8%] vs. 55 [8.4%], HR=0.54; 95% CI=0.33−0.89, P=0.007). By landmark analysis, major adverse cardiac events between 1 and 5 years occurred in 17 patients (2.8%) receiving IVUS-guidance and in 31 patients (5.2%) receiving angiography-guidance (HR=0.53, 95% CI=0.29-0.95, P=0.031).

 

CONCLUSIONS - Compared with angiography-guided stent implantation, IVUS-guided stent implantation resulted in a significantly lower rate of major adverse cardiac events up to 5 years. Sustained 5-year clinical benefits resulted from both within 1 year and from 1 to 5 years’ post-implantation.