CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Transcatheter Aortic Valve Replacement in Low-Risk Patients With Symptomatic Severe Bicuspid Aortic Valve Stenosis Randomized Evaluation of TriGuard 3 Cerebral Embolic Protection After Transcatheter Aortic Valve Replacement: REFLECT II 2020 ACC Expert Consensus Decision Pathway on Management of Conduction Disturbances in Patients Undergoing Transcatheter Aortic Valve Replacement A Report of the American College of Cardiology Solution Set Oversight Committee Association of Effective Regurgitation Orifice Area to Left Ventricular End-Diastolic Volume Ratio With Transcatheter Mitral Valve Repair OutcomesA Secondary Analysis of the COAPT Trial 5-Year Outcomes Comparing Surgical Versus Transcatheter Aortic Valve Replacement in Patients With Chronic Kidney Disease Ambulatory Electrocardiogram Monitoring in Patients Undergoing Transcatheter Aortic Valve Replacement: JACC State-of-the-Art Review Long-term dual antiplatelet-induced intestinal injury resulting in translocation of intestinal bacteria into blood circulation increased the incidence of adverse events after PCI in patients with coronary artery disease Assessment of Vascular Dysfunction in Patients Without Obstructive Coronary Artery Disease: Why, How, and When Randomized trial of simple versus complex drug-eluting stenting for bifurcation lesions: the British Bifurcation Coronary Study: old, new, and evolving strategies Evolving concepts in the management of antithrombotic therapy in patients undergoing transcatheter aortic valve implantation

Clinical TrialSeptember 2019

JOURNAL:JACC Cardiovasc Interv. Article Link

Effect of Intravascular Ultrasound-Guided Drug-Eluting Stent Implantation: Five-Year Follow-Up of the IVUS-XPL Randomized Trial

SJ Hong, GS Mintz, the IVUS-XPL Investigators. Keywords: IVUS guidance superior to angiography guidance; MACE; long-term follow-up; long lesions

ABSTRACT


OBJECTIVES - The goal of this study was to evaluate whether the beneficial effect of use of intravascular ultrasound (IVUS) is sustained for long-term follow-up.

 

BACKGROUND - The use of IVUS promoted favorable 1-year clinical outcome in the IVUS-XPL trial. It is not known, however, whether this effect is sustained for long-term follow-up.

 

METHODS - The IVUS-XPL trial randomized 1,400 patients with long coronary lesions (implanted stent length ≥28mm) to receive IVUS- (n=700) or angiography-guided (n=700) everolimus-eluting stent implantation. Five-year clinical outcomes were investigated in patients who completed the original trial. Primary outcome was the composite of major adverse cardiac events, including cardiac death, target lesion-related myocardial infarction, or ischemia-driven target lesion revascularization at 5 years, analyzed by intention-to-treat.

 

RESULTS - Five-year follow-up was completed in 1,183 patients (85%). Major adverse cardiac events at 5 years occurred in 36 patients (5.6%) receiving IVUS-guidance and in 70 patients (10.7%) receiving angiography-guidance (hazard ratio [HR]=0.50, 95% confidence interval [CI]=0.34−0.75, P=0.001). The difference was mainly driven by a lower risk of target lesion revascularization (31 [4.8%] vs. 55 [8.4%], HR=0.54; 95% CI=0.33−0.89, P=0.007). By landmark analysis, major adverse cardiac events between 1 and 5 years occurred in 17 patients (2.8%) receiving IVUS-guidance and in 31 patients (5.2%) receiving angiography-guidance (HR=0.53, 95% CI=0.29-0.95, P=0.031).

 

CONCLUSIONS - Compared with angiography-guided stent implantation, IVUS-guided stent implantation resulted in a significantly lower rate of major adverse cardiac events up to 5 years. Sustained 5-year clinical benefits resulted from both within 1 year and from 1 to 5 years’ post-implantation.