CBS 2019
CBSMD教育中心
中 文

血管内超声指导

Abstract

Recommended Article

Clinical impact of intravascular ultrasound guidance in drug-eluting stent implantation for unprotected left main coronary disease: pooled analysis at the patient-level of 4 registries Role of Proximal Optimization Technique Guided by Intravascular Ultrasound on Stent Expansion, Stent Symmetry Index, and Side-Branch Hemodynamics in Patients With Coronary Bifurcation Lesions Tissue characterisation of atherosclerotic plaque in the left main: an in vivo intravascular ultrasound radiofrequency data analysis Imaging- and physiology-guided percutaneous coronary intervention without contrast administration in advanced renal failure: a feasibility, safety, and outcome study Optical Frequency Domain Imaging Versus Intravascular Ultrasound in Percutaneous Coronary Intervention (OPINION Trial) Results From the OPINION Imaging Study Incidence and Clinical Outcomes of Stent Fractures on the Basis of 6,555 Patients and 16,482 Drug-Eluting Stents From 4 Centers Plaque composition by intravascular ultrasound and distal embolization after percutaneous coronary intervention A Randomized Study of Distal Filter Protection Versus Conventional Treatment During Percutaneous Coronary Intervention in Patients With Attenuated Plaque Identified by Intravascular Ultrasound

Review Article2017 Apr, Epub 2017 Mar 22

JOURNAL:Anatol J Cardiol. Article Link

The outcomes of intravascular ultrasound-guided drug-eluting stent implantation among patients with complex coronary lesions: a comprehensive meta-analysis of 15 clinical trials and 8,084 patients

Fan ZG, Gao XF, Tian NL et al. Keywords: intravascular ultrasound, drug-eluting stent, complex lesions, meta-analysis

ABSTRACT


OBJECTIVE - The effects of intravascular ultrasound (IVUS)-guided drug-eluting stent (DES) implantation in patients with complex coronary artery lesions remains to be controversial. This study sought to evaluate the outcomes of IVUS guidance in these patients.


METHODS- The EMBASE, Medline, and other internet sources were searched for relevant articles. The primary endpoint was major adverse cardiac events (MACE), including all-cause mortality, myocardial infarction (MI), and target-vessel revascularization (TVR). The incidence of definite/probable stent thrombosis (ST) was analyzed as the safety endpoint.


RESULTS- Fifteen clinical trials involving 8.084 patients were analyzed. MACE risk was significantly decreased following IVUS-guided DES implantation compared with coronary angiography (CAG) guidance (odds ratio [OR] 0.63, 95% confidence intervals [CI]: 0.53-0.73, p<0.001), which might mainly result from the lower all-cause mortality risk (OR 0.52, 95% CI: 0.40-0.67, p<0.001), MI (OR 0.70, 95% CI: 0.56-0.86, p=0.001), and TVR (OR 0.53, 95% CI: 0.40-0.70, p<0.001). The subgroup analyses indicated better outcomes of IVUS guidance in DES implantation for these patients with left main disease or bifurcation lesions.


CONCLUSION- IVUS guidance in DES implantation is associated with a significant reduction in MACE risk in patients with complex lesions, particularly those with left main disease or bifurcation lesions. More large and powerful randomized trials are still warranted to guide stenting decision making.