CBS 2019
CBSMD教育中心
中 文

血管内超声指导

Abstract

Recommended Article

Intravascular ultrasound-guided systematic two-stent techniques for coronary bifurcation lesions and reduced late stent thrombosis Clinical use of intracoronary imaging. Part 1: guidance and optimization of coronary interventions. An expert consensus document of the European Association of Percutaneous Cardiovascular Interventions: Endorsed by the Chinese Society of Cardiology Catastrophic catheter-induced coronary artery vasospasm successfully rescued using intravascular ultrasound imaging guidance Attenuated plaque detected by intravascular ultrasound: clinical, angiographic, and morphologic features and post-percutaneous coronary intervention complications in patients with acute coronary syndromes Effect of Intravascular Ultrasound-Guided Drug-Eluting Stent Implantation: Five-Year Follow-Up of the IVUS-XPL Randomized Trial The Role of Vascular Imaging in Guiding Routine Percutaneous Coronary Interventions: A Meta-Analysis of Bare Metal Stent and Drug-Eluting Stent Trials Intravascular ultrasound findings of early stent thrombosis after primary percutaneous intervention in acute myocardial infarction: a Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) substudy Effect of Intravascular Ultrasound-Guided vs Angiography-Guided Everolimus-Eluting Stent Implantation: The IVUS-XPL Randomized Clinical Trial

Review Article2017 Apr, Epub 2017 Mar 22

JOURNAL:Anatol J Cardiol. Article Link

The outcomes of intravascular ultrasound-guided drug-eluting stent implantation among patients with complex coronary lesions: a comprehensive meta-analysis of 15 clinical trials and 8,084 patients

Fan ZG, Gao XF, Tian NL et al. Keywords: intravascular ultrasound, drug-eluting stent, complex lesions, meta-analysis

ABSTRACT


OBJECTIVE - The effects of intravascular ultrasound (IVUS)-guided drug-eluting stent (DES) implantation in patients with complex coronary artery lesions remains to be controversial. This study sought to evaluate the outcomes of IVUS guidance in these patients.


METHODS- The EMBASE, Medline, and other internet sources were searched for relevant articles. The primary endpoint was major adverse cardiac events (MACE), including all-cause mortality, myocardial infarction (MI), and target-vessel revascularization (TVR). The incidence of definite/probable stent thrombosis (ST) was analyzed as the safety endpoint.


RESULTS- Fifteen clinical trials involving 8.084 patients were analyzed. MACE risk was significantly decreased following IVUS-guided DES implantation compared with coronary angiography (CAG) guidance (odds ratio [OR] 0.63, 95% confidence intervals [CI]: 0.53-0.73, p<0.001), which might mainly result from the lower all-cause mortality risk (OR 0.52, 95% CI: 0.40-0.67, p<0.001), MI (OR 0.70, 95% CI: 0.56-0.86, p=0.001), and TVR (OR 0.53, 95% CI: 0.40-0.70, p<0.001). The subgroup analyses indicated better outcomes of IVUS guidance in DES implantation for these patients with left main disease or bifurcation lesions.


CONCLUSION- IVUS guidance in DES implantation is associated with a significant reduction in MACE risk in patients with complex lesions, particularly those with left main disease or bifurcation lesions. More large and powerful randomized trials are still warranted to guide stenting decision making.