CBS 2019
CBSMD教育中心
中 文

血管内超声指导

Abstract

Recommended Article

Clinical impact of intravascular ultrasound guidance in drug-eluting stent implantation for unprotected left main coronary disease: pooled analysis at the patient-level of 4 registries Role of Proximal Optimization Technique Guided by Intravascular Ultrasound on Stent Expansion, Stent Symmetry Index, and Side-Branch Hemodynamics in Patients With Coronary Bifurcation Lesions Tissue characterisation of atherosclerotic plaque in the left main: an in vivo intravascular ultrasound radiofrequency data analysis Imaging- and physiology-guided percutaneous coronary intervention without contrast administration in advanced renal failure: a feasibility, safety, and outcome study Optical Frequency Domain Imaging Versus Intravascular Ultrasound in Percutaneous Coronary Intervention (OPINION Trial) Results From the OPINION Imaging Study Incidence and Clinical Outcomes of Stent Fractures on the Basis of 6,555 Patients and 16,482 Drug-Eluting Stents From 4 Centers Plaque composition by intravascular ultrasound and distal embolization after percutaneous coronary intervention A Randomized Study of Distal Filter Protection Versus Conventional Treatment During Percutaneous Coronary Intervention in Patients With Attenuated Plaque Identified by Intravascular Ultrasound

Clinical Trial2013 Feb;81(3):456-63.

JOURNAL:Catheter Cardiovasc Interv. Article Link

Intravascular ultrasound-guided systematic two-stent techniques for coronary bifurcation lesions and reduced late stent thrombosis

Chen SL, Ye F, Zhang JJ et al. Keywords: IVUS; coronary bifurcation lesions; two-stent technique; late stent thrombosis;

ABSTRACT


BACKGROUNDThe effects of intravascular ultrasound (IVUS)-guided complex approaches using drug-eluting stents (DES) for coronary bifurcation lesions on clinical outcomes has not yet been studied in detail.


OBJECTIVEOur objective was to analyze the difference in 1-year outcomes following two-stent techniques involving implantation of DES for coronary bifurcation lesions between IVUS-guided and angiography-guided groups.

METHODSFrom May 26, 2007 to March 24, 2010, 628 patients received two-stent techniques (324 in the IVUS-guided group and 304 angiography-guided) and were prospectively studied. We compared major adverse cardiac events (MACE, including cardiac death, stent thrombosis [ST], myocardial infarction [MI] and target lesion/vessel revascularization) at 12-months follow-up, before and after adjusting for propensity score matching.

RESULTSAt 12-months after the indexed procedure, patients in the angiography-guided group had significantly increased in-stent restenosis. Compared to the angiography-guided group, the IVUS-guided group had a significantly lower overall unadjusted ST rate (1.2% vs. 6.9%, P < 0.001), definite ST (0.6% vs. 5.3%, P < 0.001), late ST (0.6% vs. 4.3%, P = 0.003), MI (4.6% vs. 8.9%, P = 0.038) and cardiac death (0.9% vs. 3.3%, P = 0.049). By propensity score matching, 123 paired patients were matched. The late ST at 12-months follow-up was 0% in the IVUS-guided group versus 4.9% in the angiography-guided group (P = 0.029), resulting in significant differences in ST-elevation MI between the two groups (2.4% vs. 9.8%, P = 0.030).

CONCLUSIONSThe IVUS-guided two-stent technique was associated with significantly reduced late stent thrombosis, with a resultant reduction in ST-elevation MI. © 2012 Wiley Periodicals, Inc.

Copyright © 2012 Wiley Periodicals, Inc.