CBS 2019
CBSMD教育中心
中 文

血管内超声指导

Abstract

Recommended Article

Impact of plaque components on no-reflow phenomenon after stent deployment in patients with acute coronary syndrome: a virtual histology-intravascular ultrasound analysis Impact of the Use of Intravascular Imaging on Patients Who Underwent Orbital Atherectomy Atherosclerotic plaque with ultrasonic attenuation affects coronary reflow and infarct size in patients with acute coronary syndrome: an intravascular ultrasound study The relationship between attenuated plaque identified by intravascular ultrasound and no-reflow after stenting in acute myocardial infarction: the HORIZONS-AMI (Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction) trial Meta-analysis of outcomes after intravascular ultrasound-guided versus angiography-guided drug-eluting stent implantation in 26,503 patients enrolled in three randomized trials and 14 observational studies Intravascular Ultrasound Guidance Is Associated With Better Outcome in Patients Undergoing Unprotected Left Main Coronary Artery Stenting Compared With Angiography Guidance Alone Intravascular Ultrasound Guidance Reduces Cardiac Death and Coronary Revascularization in Patients Undergoing Drug-Eluting Stent Implantation: Results From a Meta-Analysis of 9 Randomized Trials and 4724 Patients Intravascular Ultrasound-Guided Versus Angiography-Guided Implantation of Drug-Eluting Stent in All-Comers: The ULTIMATE trial

Clinical Trial2013 Feb;81(3):456-63.

JOURNAL:Catheter Cardiovasc Interv. Article Link

Intravascular ultrasound-guided systematic two-stent techniques for coronary bifurcation lesions and reduced late stent thrombosis

Chen SL, Ye F, Zhang JJ et al. Keywords: IVUS; coronary bifurcation lesions; two-stent technique; late stent thrombosis;

ABSTRACT


BACKGROUNDThe effects of intravascular ultrasound (IVUS)-guided complex approaches using drug-eluting stents (DES) for coronary bifurcation lesions on clinical outcomes has not yet been studied in detail.


OBJECTIVEOur objective was to analyze the difference in 1-year outcomes following two-stent techniques involving implantation of DES for coronary bifurcation lesions between IVUS-guided and angiography-guided groups.

METHODSFrom May 26, 2007 to March 24, 2010, 628 patients received two-stent techniques (324 in the IVUS-guided group and 304 angiography-guided) and were prospectively studied. We compared major adverse cardiac events (MACE, including cardiac death, stent thrombosis [ST], myocardial infarction [MI] and target lesion/vessel revascularization) at 12-months follow-up, before and after adjusting for propensity score matching.

RESULTSAt 12-months after the indexed procedure, patients in the angiography-guided group had significantly increased in-stent restenosis. Compared to the angiography-guided group, the IVUS-guided group had a significantly lower overall unadjusted ST rate (1.2% vs. 6.9%, P < 0.001), definite ST (0.6% vs. 5.3%, P < 0.001), late ST (0.6% vs. 4.3%, P = 0.003), MI (4.6% vs. 8.9%, P = 0.038) and cardiac death (0.9% vs. 3.3%, P = 0.049). By propensity score matching, 123 paired patients were matched. The late ST at 12-months follow-up was 0% in the IVUS-guided group versus 4.9% in the angiography-guided group (P = 0.029), resulting in significant differences in ST-elevation MI between the two groups (2.4% vs. 9.8%, P = 0.030).

CONCLUSIONSThe IVUS-guided two-stent technique was associated with significantly reduced late stent thrombosis, with a resultant reduction in ST-elevation MI. © 2012 Wiley Periodicals, Inc.

Copyright © 2012 Wiley Periodicals, Inc.