CBS 2019
CBSMD教育中心
中 文

血管内超声指导

Abstract

Recommended Article

Impact of plaque components on no-reflow phenomenon after stent deployment in patients with acute coronary syndrome: a virtual histology-intravascular ultrasound analysis Coronary artery imaging with intravascular high-frequency ultrasound Usefulness of minimum stent cross sectional area as a predictor of angiographic restenosis after primary percutaneous coronary intervention in acute myocardial infarction (from the HORIZONS-AMI Trial IVUS substudy) Randomized comparison of clinical outcomes between intravascular ultrasound and angiography-guided drug-eluting stent implantation for long coronary artery stenoses Effects of Intravascular Ultrasound-Guided Versus Angiography-Guided New-Generation Drug-Eluting Stent Implantation: Meta-Analysis With Individual Patient-Level Data From 2,345 Randomized Patients The relationship between attenuated plaque identified by intravascular ultrasound and no-reflow after stenting in acute myocardial infarction: the HORIZONS-AMI (Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction) trial Imaging- and physiology-guided percutaneous coronary intervention without contrast administration in advanced renal failure: a feasibility, safety, and outcome study Impact of the Use of Intravascular Imaging on Patients Who Underwent Orbital Atherectomy

Original Research2015 Aug;19(16):3012-7.

JOURNAL:Eur Rev Med Pharmacol Sci. Article Link

The impact of intravascular ultrasound guidance during drug eluting stent implantation on angiographic outcomes

Yazici HU, Agamaliyev M, Aydar Y et al. Keywords: IVUS guided PCI; DES; outcome; minimal luminal diameter; net acute gain

ABSTRACT


OBJECTIVE - Major limitation for the use of stent in the treatment of coronary artery disease is development of stent restenosis. The impact of intravascular ultrasound (IVUS) guidance during drug eluting stent (DES) implantation is presently not yet well established.


PATIENTS AND METHODS - For the present study, we included 30 patients who received DES with IVUS-guided stenting (Group A) and 30 patients receiving the DES without IVUS-guided stenting (Group B). The patients were evaluated for their ninth month control angiographies and were followed during two years for the development of relevant clinical events after the DES implantations. The angiographic and clinical results were compared between the groups.


RESULTS - After the percutaneous intervention, the minimal luminal diameter and net acute gain were significantly increased in Group A in respect to Group B (3.3 ± 0.34 vs. 2.8 ± 0.33, p < 0.01). Moreover, the rate for performing post-dilatation following stent implantation was higher in Group A than in Group B (p = 0.01). By contrast, stent restenosis rates were similar between the groups (p > 0.3).


CONCLUSIONS - The present results indicate that the use of IVUS for the implantation of DES can increase the success rate of the intervention. The IVUS guidance during DES implantation can be complementary percutaneous intervention, in particularly by detecting the situations that need for post-dilatation.