Sustainable Antirestenosis Effect With a Low-Dose Drug-Coated Balloon: The ILLUMENATE European Randomized Clinical Trial 2-Year Results Comparison of 2 Different Drug-Coated Balloons in In-Stent Restenosis: The RESTORE ISR China Randomized Trial Applications of left ventricular strain measurements to patients undergoing chemotherapy Abnormalities in 3-Dimensional Left Ventricular Mechanics With Anthracycline Chemotherapy Are Associated With Systolic and Diastolic Dysfunction Trends in Utilization of, and Comparative Safety and Effectiveness of Orbital and Rotational Atherectomy Survival After Coronary Revascularization With Paclitaxel-Coated Balloons Drug-Coated Balloons: A Safe and Effective Alternative to Drug-Eluting Stents in Small Vessel Coronary Artery Disease Treatment of Drug-Eluting Stent In-Stent Restenosis With Drug-Eluting Balloons: A Systematic Review and Meta-Analysis

Clinical TrialVolume 11, Issue 23, December 2018

JOURNAL:JACC Cardiovasc Interv. Article Link

Sustainable Antirestenosis Effect With a Low-Dose Drug-Coated Balloon: The ILLUMENATE European Randomized Clinical Trial 2-Year Results

M Brodmann, M Werner, the ILLUMENATE EU RCT Investigators. Keywords: claudication; drug-coated balloon; drug-eluting balloon; peripheral artery disease; superficial femoral artery

ABSTRACT



OBJECTIVES - The aim of this study was to assess the safety and effectiveness of a next-generation low-dose drug-coated balloon (DCB) designed to optimize the amount of drug transferred into the vessel wall and to maximize the amount of time the drug resides in the vessel wall.


BACKGROUND - Several randomized controlled studies evaluating various DCBs have demonstrated a significantly higher patency rate compared with noncoated percutaneous transluminal angioplasty balloons at 1 year. However, the data are limited and vary by DCB at longer follow-up time points. An earlier generation low-dose DCB failed to demonstrate significant treatment effect at 2 years, raising questions regarding the durability of low-dose DCBs.


METHODS - In this prospective, multicenter trial, 294 patients were randomized (3:1) to treatment with a DCB or an uncoated percutaneous transluminal angioplasty balloon. Assessments at 2 years included primary patency with duplex ultrasonography, clinically driven target lesion revascularization, and functional outcomes.


RESULTS - Primary patency at 2 years was significantly higher in the DCB cohort (75.9% vs. 61.0%; p = 0.025), and the rate of clinically driven target lesion revascularization was significantly lower (12.1% vs. 30.5%; p < 0.001). There were no major limb amputations in either group. The rates of all-cause (6.5% vs. 5.1%; p = 1.00) and cardiovascular-related (1.6% vs. 1.7%; p = 1.00) mortality were similar between groups. Functional improvements over baseline were sustained in both groups, with 60% fewer reinterventions in the DCB group.


CONCLUSIONS - A sustained treatment effect is achievable with a low-dose DCB with an optimized coating formulation. This trial demonstrated for the first time a statistically significantly higher primary patency rate for a low-dose DCB versus PTA at 2 years. (CVI Drug Coated Balloon European Randomized Clinical Trial; NCT01858363)