CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Utility of intravascular ultrasound guidance in patients undergoing percutaneous coronary intervention for type C lesions Intravascular ultrasound-guided drug-eluting stent implantation: An updated meta-analysis of randomized control trials and observational studies Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial Stage-dependent differential effects of interleukin-1 isoforms on experimental atherosclerosis Association of Reduced Apical Untwisting With Incident HF in Asymptomatic Patients With HF Risk Factors Health Status After Transcatheter Versus Surgical Aortic Valve Replacement in Low-Risk Patients With Aortic Stenosis A new strategy for discontinuation of dual antiplatelet therapy: the RESET Trial (REal Safety and Efficacy of 3-month dual antiplatelet Therapy following Endeavor zotarolimus-eluting stent implantation) Dual-antiplatelet treatment beyond 1 year after drug-eluting stent implantation (ARCTIC-Interruption): a randomised trial Negative Risk Markers for Cardiovascular Events in the Elderly The effect of complete percutaneous revascularisation with and without intravascular ultrasound guidance in the drugeluting stent era

Clinical TrialVolume 72, Issue 6, August 2018

JOURNAL:J Am Coll Cardiol. Article Link

Ranolazine in High-Risk Patients With Implanted Cardioverter-Defibrillators - The RAID Trial

W Zareba, JP Daubert, CA Beck et al. Keywords: implantable cardioverter-defibrillator; ranolazine; ventricular fibrillation; ventricular tachycardia

ABSTRACT


BACKGROUND - Ventricular tachycardia (VT) and ventricular fibrillation (VF) remain a challenging problem in patients with implantable cardioverter-defibrillators (ICDs).


OBJECTIVES - This study aimed to determine whether ranolazine administration decreases the likelihood of VT, VF, or death in patients with an ICD.

METHODS - This was double-blind, placebo-controlled clinical trial in which high-risk ICD patients with ischemic or nonischemic cardiomyopathy were randomized to 1,000 mg ranolazine twice a day or placebo. The primary endpoint was VT or VF requiring appropriate ICD therapy or death, whichever occurred first. Pre-specified secondary endpoints included ICD shock for VT, VF, or death and recurrent VT or VF requiring ICD therapy.

RESULTS - Among 1,012 ICD patients (510 randomized to ranolazine and 502 to placebo) the mean age was 64 ± 10 years and 18% were women. During 28 ± 16 months of follow-up there were 372 (37%) patients with primary endpoint, 270 (27%) patients with VT or VF, and 148 (15%) deaths. The blinded study drug was discontinued in 199 (39.6%) patients receiving placebo and in 253 (49.6%) patients receiving ranolazine (p = 0.001). The hazard ratio for ranolazine versus placebo was 0.84 (95% confidence interval: 0.67 to 1.05; p = 0.117) for VT, VF, or death. In a pre-specified secondary analysis, patients randomized to ranolazine had a marginally significant lower risk of ICD therapies for recurrent VT or VF (hazard ratio: 0.70; 95% confidence interval: 0.51 to 0.96; p = 0.028). There were no other significant treatment effects in other pre-specified secondary analyses, which included individual components of the primary endpoint, inappropriate shocks, cardiac hospitalizations, and quality of life.

CONCLUSIONS - In high-risk ICD patients, treatment with ranolazine did not significantly reduce the incidence of the first VT or VF, or death. However, the study was underpowered to detect a difference in the primary endpoint. In prespecified secondary endpoint analyses, ranolazine administration was associated with a significant reduction in recurrent VT or VF requiring ICD therapy without evidence for increased mortality. (Ranolazine Implantable Cardioverter-Defibrillator Trial [RAID]; NCT01215253)