CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Use of clopidogrel with or without aspirin in patients taking oral anticoagulant therapy and undergoing percutaneous coronary intervention: an open-label, randomised, controlled trial Optimal duration of dual antiplatelet therapy after drug-eluting stent implantation: a randomized, controlled trial. Intravascular ultrasound guidance improves clinical outcomes during implantation of both first- and second-generation drug-eluting stents: a meta-analysis 2022 AHA/ACC/HFSA Guideline for the Management of Heart Failure: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines Discrepancies in Measurement of the Thoracic Aorta: JACC Review Topic of the Week Prognostic implications of baseline 6‐min walk test performance in intermediate risk patients undergoing transcatheter aortic valve replacement Outcomes 2 Years After Transcatheter Aortic Valve Replacement in Patients at Low Surgical Risk Colchicine Reduces Cardiovascular Events in Chronic Coronary Disease Economic and Quality-of-Life Outcomes of Natriuretic Peptide–Guided Therapy for Heart Failure The conductive function of biopolymer corrects myocardial scar conduction blockage and resynchronizes contraction to prevent heart failure

Clinical TrialVolume 72, Issue 6, August 2018

JOURNAL:J Am Coll Cardiol. Article Link

Ranolazine in High-Risk Patients With Implanted Cardioverter-Defibrillators - The RAID Trial

W Zareba, JP Daubert, CA Beck et al. Keywords: implantable cardioverter-defibrillator; ranolazine; ventricular fibrillation; ventricular tachycardia

ABSTRACT


BACKGROUND - Ventricular tachycardia (VT) and ventricular fibrillation (VF) remain a challenging problem in patients with implantable cardioverter-defibrillators (ICDs).


OBJECTIVES - This study aimed to determine whether ranolazine administration decreases the likelihood of VT, VF, or death in patients with an ICD.

METHODS - This was double-blind, placebo-controlled clinical trial in which high-risk ICD patients with ischemic or nonischemic cardiomyopathy were randomized to 1,000 mg ranolazine twice a day or placebo. The primary endpoint was VT or VF requiring appropriate ICD therapy or death, whichever occurred first. Pre-specified secondary endpoints included ICD shock for VT, VF, or death and recurrent VT or VF requiring ICD therapy.

RESULTS - Among 1,012 ICD patients (510 randomized to ranolazine and 502 to placebo) the mean age was 64 ± 10 years and 18% were women. During 28 ± 16 months of follow-up there were 372 (37%) patients with primary endpoint, 270 (27%) patients with VT or VF, and 148 (15%) deaths. The blinded study drug was discontinued in 199 (39.6%) patients receiving placebo and in 253 (49.6%) patients receiving ranolazine (p = 0.001). The hazard ratio for ranolazine versus placebo was 0.84 (95% confidence interval: 0.67 to 1.05; p = 0.117) for VT, VF, or death. In a pre-specified secondary analysis, patients randomized to ranolazine had a marginally significant lower risk of ICD therapies for recurrent VT or VF (hazard ratio: 0.70; 95% confidence interval: 0.51 to 0.96; p = 0.028). There were no other significant treatment effects in other pre-specified secondary analyses, which included individual components of the primary endpoint, inappropriate shocks, cardiac hospitalizations, and quality of life.

CONCLUSIONS - In high-risk ICD patients, treatment with ranolazine did not significantly reduce the incidence of the first VT or VF, or death. However, the study was underpowered to detect a difference in the primary endpoint. In prespecified secondary endpoint analyses, ranolazine administration was associated with a significant reduction in recurrent VT or VF requiring ICD therapy without evidence for increased mortality. (Ranolazine Implantable Cardioverter-Defibrillator Trial [RAID]; NCT01215253)