CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Two-Year Outcomes and Predictors of Target Lesion Revascularization for Non-Left Main Coronary Bifurcation Lesions Following Two-Stent Strategy With 2nd-Generation Drug-Eluting Stents Rotational atherectomy and new-generation drug-eluting stent implantation Impact of Artificial Intelligence on Interventional Cardiology: From Decision-Making Aid to Advanced Interventional Procedure Assistance Nonproportional Hazards for Time-to-Event Outcomes in Clinical Trials: JACC Review Topic of the Week Ticagrelor with or without Aspirin in High-Risk Patients after PCI Vascular response and healing profile of everolimus-eluting bioresorbable vascular scaffolds for percutaneous treatment of chronic total coronary occlusions: A one-year optical coherence tomography analysis from the GHOST-CTO registry Comparative Accuracy of Focused Cardiac Ultrasonography and Clinical Examination for Left Ventricular Dysfunction and Valvular Heart Disease: A Systematic Review and Meta-analysis Timing and Causes of Unplanned Readmissions After Percutaneous Coronary Intervention: Insights From the Nationwide Readmission Database The optimal duration of dual antiplatelet therapy after coronary stent implantation: to go too far is as bad as to fall short Rare Genetic Variants Associated With Sudden Cardiac Death in Adults

Original Research2014 Sep 1;84(3):406-13.

JOURNAL:Catheter Cardiovasc Interv. Article Link

Impact of myocardial supply area on the transstenotic hemodynamics as determined by fractional flow reserve

Shiono Y1 Kubo T, Tanaka A et al. Keywords: coronary angiography; fractional flow reserve; ischemic heart disease

ABSTRACT


OBJECTIVESThe aim of this study was to investigate the impact of myocardial area supplied by the coronary artery on fractional flow reserve (FFR).


BACKGROUND - Various factors other than the degree of epicardial stenosis influence the physiological significance of a coronary artery stenosis.

METHODS - A total of 296 coronary lesions in 217 patients were analyzed by quantitative coronary angiography and FFR. Myocardial area supplied by the coronary artery distal to the stenosis was evaluated by angiography using a modified version of the Alberta Provincial Project for Outcome Assessment in Coronary Heart Disease (APPROACH) score.

RESULTS - Percent diameter stenosis of the coronary lesion was 57 ± 15% (mean ± standard deviation). FFR <0.80 was seen in 132 (45%) lesions. FFR was significantly correlated with minimum lumen diameter (r = 0.584, P <0.001), percent diameter stenosis (r = -0.565, P <0.001), lesion length (r = -0.306, P <0.001), and myocardial supply area (r = -0.504, P <0.001). Multivariate logistic analysis demonstrated that minimum lumen diameter (odds ratio [OR] = 0.031, 95% confidence interval [CI] = 0.013-0.076, P < 0.001), lesion length (OR = 1.038, 95% CI = 1.009-1.069, P = 0.001), and myocardial supply area (OR = 1.113, 95% CI = 1.079-1.147, P <0.001) were independent determinants for FFR <0.80.

CONCLUSIONS - FFR, which is the index of physiological significance of coronary artery stenosis, is influenced by myocardial supply area distal to the stenosis as well as by its own minimal lumen diameter and lesion length.

© 2013 Wiley Periodicals, Inc.