CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Double kissing crush in left main coronary bifurcation lesions: A crushing blow to the rival stenting techniques In-Hospital Costs and Costs of Complications of Chronic Total Occlusion Angioplasty Insights From the OPEN-CTO Registry Long-term outcomes of rotational atherectomy of underexpanded stents. A single center experience Chronic Kidney Disease and Coronary Artery Disease Left Ventricular Assist Devices: Synergistic Model Between Technology and Medicine Diagnostic performance of stress perfusion cardiac magnetic resonance for the detection of coronary artery disease: A systematic review and meta-analysis Drug-eluting balloons in coronary interventions: the quiet revolution? Catheterization Laboratory Considerations During the Coronavirus (COVID-19) Pandemic: From the ACC’s Interventional Council and SCAI Classification of Deaths in Cardiovascular Outcomes Trials Known Unknowns and Unknown Unknowns Ejection Fraction Pros and Cons: JACC State-of-the-Art Review

Original Research2014 Sep 1;84(3):406-13.

JOURNAL:Catheter Cardiovasc Interv. Article Link

Impact of myocardial supply area on the transstenotic hemodynamics as determined by fractional flow reserve

Shiono Y1 Kubo T, Tanaka A et al. Keywords: coronary angiography; fractional flow reserve; ischemic heart disease

ABSTRACT


OBJECTIVESThe aim of this study was to investigate the impact of myocardial area supplied by the coronary artery on fractional flow reserve (FFR).


BACKGROUND - Various factors other than the degree of epicardial stenosis influence the physiological significance of a coronary artery stenosis.

METHODS - A total of 296 coronary lesions in 217 patients were analyzed by quantitative coronary angiography and FFR. Myocardial area supplied by the coronary artery distal to the stenosis was evaluated by angiography using a modified version of the Alberta Provincial Project for Outcome Assessment in Coronary Heart Disease (APPROACH) score.

RESULTS - Percent diameter stenosis of the coronary lesion was 57 ± 15% (mean ± standard deviation). FFR <0.80 was seen in 132 (45%) lesions. FFR was significantly correlated with minimum lumen diameter (r = 0.584, P <0.001), percent diameter stenosis (r = -0.565, P <0.001), lesion length (r = -0.306, P <0.001), and myocardial supply area (r = -0.504, P <0.001). Multivariate logistic analysis demonstrated that minimum lumen diameter (odds ratio [OR] = 0.031, 95% confidence interval [CI] = 0.013-0.076, P < 0.001), lesion length (OR = 1.038, 95% CI = 1.009-1.069, P = 0.001), and myocardial supply area (OR = 1.113, 95% CI = 1.079-1.147, P <0.001) were independent determinants for FFR <0.80.

CONCLUSIONS - FFR, which is the index of physiological significance of coronary artery stenosis, is influenced by myocardial supply area distal to the stenosis as well as by its own minimal lumen diameter and lesion length.

© 2013 Wiley Periodicals, Inc.