CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

The effect of complete percutaneous revascularisation with and without intravascular ultrasound guidance in the drugeluting stent era Utility of intravascular ultrasound guidance in patients undergoing percutaneous coronary intervention for type C lesions Prognostic value of coronary artery calcium screening in subjects with and without diabetes Dapagliflozin for treating chronic heart failure with reduced ejection fraction American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents Lipid-Modifying Agents, From Statins to PCSK9 Inhibitors: JACC Focus Seminar Colchicine Reduces Cardiovascular Events in Chronic Coronary Disease Relation between baseline plaque features and subsequent coronary artery remodeling determined by optical coherence tomography and intravascular ultrasound Provisional versus elective two-stent strategy for unprotected true left main bifurcation lesions: Insights from a FAILS-2 sub-study Online Quantitative Aortographic Assessment of Aortic Regurgitation After TAVR: Results of the OVAL Study

Clinical Trial2013 Feb;81(3):456-63.

JOURNAL:Catheter Cardiovasc Interv. Article Link

Intravascular ultrasound-guided systematic two-stent techniques for coronary bifurcation lesions and reduced late stent thrombosis

Chen SL, Ye F, Zhang JJ et al. Keywords: IVUS; coronary bifurcation lesions; two-stent technique; late stent thrombosis;

ABSTRACT


BACKGROUNDThe effects of intravascular ultrasound (IVUS)-guided complex approaches using drug-eluting stents (DES) for coronary bifurcation lesions on clinical outcomes has not yet been studied in detail.


OBJECTIVEOur objective was to analyze the difference in 1-year outcomes following two-stent techniques involving implantation of DES for coronary bifurcation lesions between IVUS-guided and angiography-guided groups.

METHODSFrom May 26, 2007 to March 24, 2010, 628 patients received two-stent techniques (324 in the IVUS-guided group and 304 angiography-guided) and were prospectively studied. We compared major adverse cardiac events (MACE, including cardiac death, stent thrombosis [ST], myocardial infarction [MI] and target lesion/vessel revascularization) at 12-months follow-up, before and after adjusting for propensity score matching.

RESULTSAt 12-months after the indexed procedure, patients in the angiography-guided group had significantly increased in-stent restenosis. Compared to the angiography-guided group, the IVUS-guided group had a significantly lower overall unadjusted ST rate (1.2% vs. 6.9%, P < 0.001), definite ST (0.6% vs. 5.3%, P < 0.001), late ST (0.6% vs. 4.3%, P = 0.003), MI (4.6% vs. 8.9%, P = 0.038) and cardiac death (0.9% vs. 3.3%, P = 0.049). By propensity score matching, 123 paired patients were matched. The late ST at 12-months follow-up was 0% in the IVUS-guided group versus 4.9% in the angiography-guided group (P = 0.029), resulting in significant differences in ST-elevation MI between the two groups (2.4% vs. 9.8%, P = 0.030).

CONCLUSIONSThe IVUS-guided two-stent technique was associated with significantly reduced late stent thrombosis, with a resultant reduction in ST-elevation MI. © 2012 Wiley Periodicals, Inc.

Copyright © 2012 Wiley Periodicals, Inc.