CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

2019 ACC/AHA/ASE Advanced Training Statement on Echocardiography (Revision of the 2003 ACC/AHA Clinical Competence Statement on Echocardiography): A Report of the ACC Competency Management Committee Regional Heterogeneity in the Coronary Vascular Response in Women With Chest Pain and Nonobstructive Coronary Artery Disease Safety and efficacy of a self-expanding versus a balloon-expandable bioprosthesis for transcatheter aortic valve replacement in patients with symptomatic severe aortic stenosis: a randomised non-inferiority trial Transcatheter Aortic Valve Replacement in Low-risk Patients With Bicuspid Aortic Valve Stenosis Dual Antiplatelet Therapy Duration: Reconciling the Inconsistencies Effects of Intravascular Ultrasound-Guided Versus Angiography-Guided New-Generation Drug-Eluting Stent Implantation: Meta-Analysis With Individual Patient-Level Data From 2,345 Randomized Patients Haemodynamic-guided management of heart failure (GUIDE-HF): a randomised controlled trial A trial to evaluate the effect of the sodium-glucose co-transporter 2 inhibitor dapagliflozin on morbidity and mortality in patients with heart failure and reduced left ventricular ejection fraction (DAPA-HF) Aspirin with or without Clopidogrel after Transcatheter Aortic-Valve Implantation Bridging the Gap Between Epigenetic and Genetic in PAH

Review ArticleVolume 75, Issue 9, March 2020

JOURNAL:J Am Coll Cardiol. Article Link

Drug-Coated Balloon for De Novo Coronary Artery Disease: JACC State-of-the-Art Review

C Yerasi, BC Case, BJ Forrestal et al. Keywords: CAD; DCB; drug-eluting balloon; paclitaxel-coated balloon; paclitaxel-eluting balloon; small-vessel disease

ABSTRACT


Percutaneous coronary intervention with a drug-eluting stent is the most common mode of revascularization for coronary artery disease. However, restenosis rates remain high. Non-stent-based local drug delivery by a drug-coated balloon (DCB) has been investigated, as it leaves no metallic mesh. A DCB consists of a semicompliant balloon coated with antiproliferative agents encapsulated in a polymer matrix, which is released into the wall after inflation and contact with the intima. DCB have demonstrated effectiveness in treating in-stent restenosis. Clinical studies using DCB in de novo coronary artery disease have shown mixed results, with a major benefit in small-vessel disease. Differences in study results are not only due to variations in DCB technology but also to disparity in procedural approach, “leave nothing behind” or “combination therapy,” and vessel size. This review focuses on the available evidence from randomized trials and proposes a design for future clinical trials.