CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Diagnostic performance of noninvasive myocardial perfusion imaging using single-photon emission computed tomography, cardiac magnetic resonance, and positron emission tomography imaging for the detection of obstructive coronary artery disease: a meta-analysis Transcatheter aortic-valve replacement with a self-expanding prosthesis Lipid-Modifying Agents, From Statins to PCSK9 Inhibitors: JACC Focus Seminar Simple Electrocardiographic Measures Improve Sudden Arrhythmic Death Prediction in Coronary Disease Lateral Wall Dysfunction Signals Onset of Progressive Heart Failure in Left Bundle Branch Block Incidence, predictors, and outcomes associated with acute kidney injury in patients undergoing transcatheter aortic valve replacement: from the BRAVO-3 randomized trial Randomized comparison of clinical outcomes between intravascular ultrasound and angiography-guided drug-eluting stent implantation for long coronary artery stenoses Contemporary real-world outcomes of surgical aortic valve replacement in 141,905 low-risk, intermediate-risk, and high-risk patients Circadian-Regulated Cell Death in Cardiovascular Diseases Cardiac surgery following transcatheter aortic valve replacement

Review ArticleVolume 75, Issue 9, March 2020

JOURNAL:J Am Coll Cardiol. Article Link

Drug-Coated Balloon for De Novo Coronary Artery Disease: JACC State-of-the-Art Review

C Yerasi, BC Case, BJ Forrestal et al. Keywords: CAD; DCB; drug-eluting balloon; paclitaxel-coated balloon; paclitaxel-eluting balloon; small-vessel disease

ABSTRACT


Percutaneous coronary intervention with a drug-eluting stent is the most common mode of revascularization for coronary artery disease. However, restenosis rates remain high. Non-stent-based local drug delivery by a drug-coated balloon (DCB) has been investigated, as it leaves no metallic mesh. A DCB consists of a semicompliant balloon coated with antiproliferative agents encapsulated in a polymer matrix, which is released into the wall after inflation and contact with the intima. DCB have demonstrated effectiveness in treating in-stent restenosis. Clinical studies using DCB in de novo coronary artery disease have shown mixed results, with a major benefit in small-vessel disease. Differences in study results are not only due to variations in DCB technology but also to disparity in procedural approach, “leave nothing behind” or “combination therapy,” and vessel size. This review focuses on the available evidence from randomized trials and proposes a design for future clinical trials.