CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Association Between Diastolic Dysfunction and Health Status Outcomes in Patients Undergoing Transcatheter Aortic Valve Replacement Risk of Myocardial Infarction in Anticoagulated Patients With Atrial Fibrillation Skeletal muscle mitochondrial oxidative phosphorylation function in idiopathic pulmonary arterial hypertension: in vivo and in vitro study Off-hour presentation and outcomes in patients with acute myocardial infarction: systematic review and meta-analysis Canadian SCAD Cohort Study: Shedding Light on SCAD From a United Front A sirolimus-eluting bioabsorbable polymer-coated stent (MiStent) versus an everolimus-eluting durable polymer stent (Xience) after percutaneous coronary intervention (DESSOLVE III): a randomised, single-blind, multicentre, non-inferiority, phase 3 trial Prognostic Value of Fractional Flow Reserve Measured Immediately After Drug-Eluting Stent Implantation Impact of age and comorbidity on risk stratification in idiopathic pulmonary arterial hypertension Diagnosis and Prognosis of Coronary Artery Disease with SPECT and PET A Novel Circulating MicroRNA for the Detection of Acute Myocarditis

Clinical Trial2020 May 14. [Epub ahead of print]

JOURNAL:Catheter Cardiovasc Interv. Article Link

Safety and efficacy of the bioabsorbable polymer everolimus-eluting stent versus durable polymer drug-eluting stents in high-risk patients undergoing PCI: TWILIGHT-SYNERGY

U Baber, R Chandiramani, R Mehran et al. Keywords: stent comparation; DES; bioabsorbable; durable polymer; high-risk patients

ABSTRACT


BACKGROUND - Data examining the safety and efficacy of the bioabsorbable polymer (BP) drugeluting stent (DES) as compared with durable polymer (DP) DES in highrisk patients undergoing percutaneous coronary intervention (PCI) remain limited.

 

METHODS - We conducted a prespecified analysis among patients enrolled in the TWILIGHT trial treated with the SYNERGY BPDES or a DPDES. Following successful PCI and 3 months of ticagrelor plus aspirin, patients were randomized to aspirin or placebo for 1 year; DES choice was at physician discretion. The primary endpoint was target lesion failure (TLF) [composite of cardiac death, target vessel myocardial infarction (MI), clinically driven target lesion revascularization (TLR) or definite/probable stent thrombosis (ST)].

 

RESULTS - Among enrolled participants (N = 9006), 653 were treated exclusively with the SYNERGY BPDES and 6404 with a comparator DPDES. Over 15 months, TLF rates were 6.4% and 6.1% among those receiving a SYNERGY BPDES and a DPDES, respectively (adjusted HR 0.93; 95% CI 0.64 1.35; p = 0.72). The effect of ticagrelor monotherapy on Bleeding Academic Research Consortium (BARC) type 2, 3 or 5 bleeding and the composite of allcause death, MI or stroke was uniform across DES groups (both pint >0.10).

 

CONCLUSIONS - The safety and efficacy profile of the SYNERGY BPDES is comparable to that of contemporary DPDES in highrisk patients undergoing PCI. Compared to ticagrelor plus aspirin, the effect of ticagrelor monotherapy is consistent among patients receiving SYNERGY BPDES or DPDES.

 

This article is protected by copyright. All rights reserved.