Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients Long-Term Coronary Functional Assessment of the Infarct-Related Artery Treated With Everolimus-Eluting Bioresorbable Scaffolds or Everolimus-Eluting Metallic Stents: Insights of the TROFI II Trial Canadian spontaneous coronary artery dissection cohort study: in-hospital and 30-day outcomes Improved Outcomes Associated with the use of Shock Protocols: Updates from the National Cardiogenic Shock Initiative Incidence and prognostic implication of unrecognized myocardial scar characterized by cardiac magnetic resonance in diabetic patients without clinical evidence of myocardial infarction Nonculprit Lesion Myocardial Infarction Following Percutaneous Coronary Intervention in Patients With Acute Coronary Syndrome Everolimus-Eluting Bioresorbable Scaffolds Versus Everolimus-Eluting Metallic Stents Optical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chronic total occlusions” (PRISON IV) trial Red Cell Distribution Width in Patients with Diabetes and Myocardial Infarction: an analysis from the EXAMINE trial Anatomical plaque and vessel characteristics are associated with hemodynamic indices including fractional flow reserve and coronary flow reserve: A prospective exploratory intravascular ultrasound analysis

Clinical Trial2020 May 14. [Epub ahead of print]

JOURNAL:Catheter Cardiovasc Interv. Article Link

Safety and efficacy of the bioabsorbable polymer everolimus-eluting stent versus durable polymer drug-eluting stents in high-risk patients undergoing PCI: TWILIGHT-SYNERGY

U Baber, R Chandiramani, R Mehran et al. Keywords: stent comparation; DES; bioabsorbable; durable polymer; high-risk patients

ABSTRACT


BACKGROUND - Data examining the safety and efficacy of the bioabsorbable polymer (BP) drugeluting stent (DES) as compared with durable polymer (DP) DES in highrisk patients undergoing percutaneous coronary intervention (PCI) remain limited.

 

METHODS - We conducted a prespecified analysis among patients enrolled in the TWILIGHT trial treated with the SYNERGY BPDES or a DPDES. Following successful PCI and 3 months of ticagrelor plus aspirin, patients were randomized to aspirin or placebo for 1 year; DES choice was at physician discretion. The primary endpoint was target lesion failure (TLF) [composite of cardiac death, target vessel myocardial infarction (MI), clinically driven target lesion revascularization (TLR) or definite/probable stent thrombosis (ST)].

 

RESULTS - Among enrolled participants (N = 9006), 653 were treated exclusively with the SYNERGY BPDES and 6404 with a comparator DPDES. Over 15 months, TLF rates were 6.4% and 6.1% among those receiving a SYNERGY BPDES and a DPDES, respectively (adjusted HR 0.93; 95% CI 0.64 1.35; p = 0.72). The effect of ticagrelor monotherapy on Bleeding Academic Research Consortium (BARC) type 2, 3 or 5 bleeding and the composite of allcause death, MI or stroke was uniform across DES groups (both pint >0.10).

 

CONCLUSIONS - The safety and efficacy profile of the SYNERGY BPDES is comparable to that of contemporary DPDES in highrisk patients undergoing PCI. Compared to ticagrelor plus aspirin, the effect of ticagrelor monotherapy is consistent among patients receiving SYNERGY BPDES or DPDES.

 

This article is protected by copyright. All rights reserved.